rt-thread/bsp/imxrt/libraries/MIMXRT1170/MIMXRT1176/drivers/fsl_rdc_sema42.h

195 lines
5.7 KiB
C

/*
* Copyright 2017-2020 NXP
* All rights reserved.
*
* SPDX-License-Identifier: BSD-3-Clause
*/
#ifndef _FSL_RDC_SEMA42_H_
#define _FSL_RDC_SEMA42_H_
#include "fsl_common.h"
/*!
* @addtogroup rdc_sema42
* @{
*/
/******************************************************************************
* Definitions
*****************************************************************************/
/*! @name Driver version */
/*@{*/
/*! @brief RDC_SEMA42 driver version */
#define FSL_RDC_SEMA42_DRIVER_VERSION (MAKE_VERSION(2, 0, 3))
/*@}*/
/*! @brief The number to reset all RDC_SEMA42 gates. */
#define RDC_SEMA42_GATE_NUM_RESET_ALL (64U)
#if defined(RDC_SEMAPHORE_GATE_COUNT)
/*! @brief RDC_SEMA42 gate n register address. */
#define RDC_SEMA42_GATEn(base, n) ((base)->GATE[(n)])
/*! @brief RDC_SEMA42 gate count. */
#define RDC_SEMA42_GATE_COUNT (RDC_SEMAPHORE_GATE_COUNT)
#else /* RDC_SEMAPHORE_GATE_COUNT */
/*! @brief RDC_SEMA42 gate n register address. */
#define RDC_SEMA42_GATEn(base, n) (((volatile uint8_t *)(&((base)->GATE0)))[(n)])
/*! @brief RDC_SEMA42 gate count. */
#define RDC_SEMA42_GATE_COUNT (64U)
/* Compatible remap. */
#define RDC_SEMAPHORE_GATE_GTFSM_MASK RDC_SEMAPHORE_GATE0_GTFSM_MASK
#endif /* RDC_SEMAPHORE_GATE_COUNT */
/*******************************************************************************
* API
******************************************************************************/
#if defined(__cplusplus)
extern "C" {
#endif
/*!
* @brief Initializes the RDC_SEMA42 module.
*
* This function initializes the RDC_SEMA42 module. It only enables the clock but does
* not reset the gates because the module might be used by other processors
* at the same time. To reset the gates, call either RDC_SEMA42_ResetGate or
* RDC_SEMA42_ResetAllGates function.
*
* @param base RDC_SEMA42 peripheral base address.
*/
void RDC_SEMA42_Init(RDC_SEMAPHORE_Type *base);
/*!
* @brief De-initializes the RDC_SEMA42 module.
*
* This function de-initializes the RDC_SEMA42 module. It only disables the clock.
*
* @param base RDC_SEMA42 peripheral base address.
*/
void RDC_SEMA42_Deinit(RDC_SEMAPHORE_Type *base);
/*!
* @brief Tries to lock the RDC_SEMA42 gate.
*
* This function tries to lock the specific RDC_SEMA42 gate. If the gate has been
* locked by another processor, this function returns an error code.
*
* @param base RDC_SEMA42 peripheral base address.
* @param gateNum Gate number to lock.
* @param masterIndex Current processor master index.
* @param domainId Current processor domain ID.
*
* @retval kStatus_Success Lock the sema42 gate successfully.
* @retval kStatus_Failed Sema42 gate has been locked by another processor.
*/
status_t RDC_SEMA42_TryLock(RDC_SEMAPHORE_Type *base, uint8_t gateNum, uint8_t masterIndex, uint8_t domainId);
/*!
* @brief Locks the RDC_SEMA42 gate.
*
* This function locks the specific RDC_SEMA42 gate. If the gate has been
* locked by other processors, this function waits until it is unlocked and then
* lock it.
*
* @param base RDC_SEMA42 peripheral base address.
* @param gateNum Gate number to lock.
* @param masterIndex Current processor master index.
* @param domainId Current processor domain ID.
*/
void RDC_SEMA42_Lock(RDC_SEMAPHORE_Type *base, uint8_t gateNum, uint8_t masterIndex, uint8_t domainId);
/*!
* @brief Unlocks the RDC_SEMA42 gate.
*
* This function unlocks the specific RDC_SEMA42 gate. It only writes unlock value
* to the RDC_SEMA42 gate register. However, it does not check whether the RDC_SEMA42 gate is locked
* by the current processor or not. As a result, if the RDC_SEMA42 gate is not locked by the current
* processor, this function has no effect.
*
* @param base RDC_SEMA42 peripheral base address.
* @param gateNum Gate number to unlock.
*/
static inline void RDC_SEMA42_Unlock(RDC_SEMAPHORE_Type *base, uint8_t gateNum)
{
assert(gateNum < RDC_SEMA42_GATE_COUNT);
RDC_SEMA42_GATEn(base, gateNum) = 0U;
}
/*!
* @brief Gets which master has currently locked the gate.
*
* @param base RDC_SEMA42 peripheral base address.
* @param gateNum Gate number.
*
* @return Return -1 if the gate is not locked by any master, otherwise return the
* master index.
*/
static inline int32_t RDC_SEMA42_GetLockMasterIndex(RDC_SEMAPHORE_Type *base, uint8_t gateNum)
{
assert(gateNum < RDC_SEMA42_GATE_COUNT);
uint8_t regGate = RDC_SEMA42_GATEn(base, gateNum);
return (int32_t)((uint8_t)(regGate & RDC_SEMAPHORE_GATE_GTFSM_MASK)) - 1;
}
/*!
* @brief Gets which domain has currently locked the gate.
*
* @param base RDC_SEMA42 peripheral base address.
* @param gateNum Gate number.
*
* @return Return -1 if the gate is not locked by any domain, otherwise return the
* domain ID.
*/
int32_t RDC_SEMA42_GetLockDomainID(RDC_SEMAPHORE_Type *base, uint8_t gateNum);
/*!
* @brief Resets the RDC_SEMA42 gate to an unlocked status.
*
* This function resets a RDC_SEMA42 gate to an unlocked status.
*
* @param base RDC_SEMA42 peripheral base address.
* @param gateNum Gate number.
*
* @retval kStatus_Success RDC_SEMA42 gate is reset successfully.
* @retval kStatus_Failed Some other reset process is ongoing.
*/
status_t RDC_SEMA42_ResetGate(RDC_SEMAPHORE_Type *base, uint8_t gateNum);
/*!
* @brief Resets all RDC_SEMA42 gates to an unlocked status.
*
* This function resets all RDC_SEMA42 gate to an unlocked status.
*
* @param base RDC_SEMA42 peripheral base address.
*
* @retval kStatus_Success RDC_SEMA42 is reset successfully.
* @retval kStatus_RDC_SEMA42_Reseting Some other reset process is ongoing.
*/
static inline status_t RDC_SEMA42_ResetAllGates(RDC_SEMAPHORE_Type *base)
{
return RDC_SEMA42_ResetGate(base, RDC_SEMA42_GATE_NUM_RESET_ALL);
}
#if defined(__cplusplus)
}
#endif
/*!
* @}
*/
#endif /* _FSL_RDC_SEMA42_H_ */