1987 lines
70 KiB
C
1987 lines
70 KiB
C
|
//*****************************************************************************
|
||
|
//
|
||
|
// pwm.c - API for the PWM modules
|
||
|
//
|
||
|
// Copyright (c) 2005-2017 Texas Instruments Incorporated. All rights reserved.
|
||
|
// Software License Agreement
|
||
|
//
|
||
|
// Redistribution and use in source and binary forms, with or without
|
||
|
// modification, are permitted provided that the following conditions
|
||
|
// are met:
|
||
|
//
|
||
|
// Redistributions of source code must retain the above copyright
|
||
|
// notice, this list of conditions and the following disclaimer.
|
||
|
//
|
||
|
// Redistributions in binary form must reproduce the above copyright
|
||
|
// notice, this list of conditions and the following disclaimer in the
|
||
|
// documentation and/or other materials provided with the
|
||
|
// distribution.
|
||
|
//
|
||
|
// Neither the name of Texas Instruments Incorporated nor the names of
|
||
|
// its contributors may be used to endorse or promote products derived
|
||
|
// from this software without specific prior written permission.
|
||
|
//
|
||
|
// THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
|
||
|
// "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
|
||
|
// LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
|
||
|
// A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT
|
||
|
// OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
|
||
|
// SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
|
||
|
// LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
|
||
|
// DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
|
||
|
// THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
|
||
|
// (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
|
||
|
// OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! \addtogroup pwm_api
|
||
|
//! @{
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
|
||
|
#include <ti/devices/msp432e4/inc/msp432e411y.h>
|
||
|
#include "types.h"
|
||
|
#include <stdbool.h>
|
||
|
#include <stdint.h>
|
||
|
#include "inc/hw_pwm.h"
|
||
|
#include "inc/hw_sysctl.h"
|
||
|
#include "debug.h"
|
||
|
#include "interrupt.h"
|
||
|
#include "pwm.h"
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
// Misc macros for manipulating the encoded generator and output defines used
|
||
|
// by the API.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
#define PWM_GEN_BADDR(_mod_, _gen_) \
|
||
|
((_mod_) + (_gen_))
|
||
|
#define PWM_GEN_EXT_BADDR(_mod_, _gen_) \
|
||
|
((_mod_) + PWM_GEN_EXT_0 + \
|
||
|
((_gen_) - PWM_GEN_0) * 2)
|
||
|
#define PWM_OUT_BADDR(_mod_, _out_) \
|
||
|
((_mod_) + ((_out_) & 0xFFFFFFC0))
|
||
|
#define PWM_IS_OUTPUT_ODD(_out_) \
|
||
|
((_out_) & 0x00000001)
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! \internal
|
||
|
//! Checks a PWM generator number.
|
||
|
//!
|
||
|
//! \param ui32Gen is the generator number.
|
||
|
//!
|
||
|
//! This function determines if a PWM generator number is valid.
|
||
|
//!
|
||
|
//! \return Returnes \b true if the generator number is valid and \b false
|
||
|
//! otherwise.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
#ifdef DEBUG
|
||
|
static bool
|
||
|
_PWMGenValid(uint32_t ui32Gen)
|
||
|
{
|
||
|
return ((ui32Gen == PWM_GEN_0) || (ui32Gen == PWM_GEN_1) ||
|
||
|
(ui32Gen == PWM_GEN_2) || (ui32Gen == PWM_GEN_3));
|
||
|
}
|
||
|
#endif
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! \internal
|
||
|
//! Checks a PWM output number.
|
||
|
//!
|
||
|
//! \param ui32PWMOut is the output number.
|
||
|
//!
|
||
|
//! This function determines if a PWM output number is valid.
|
||
|
//!
|
||
|
//! \return Returns \b true if the output number is valid and \b false
|
||
|
//! otherwise.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
#ifdef DEBUG
|
||
|
static bool
|
||
|
_PWMOutValid(uint32_t ui32PWMOut)
|
||
|
{
|
||
|
return ((ui32PWMOut == PWM_OUT_0) || (ui32PWMOut == PWM_OUT_1) ||
|
||
|
(ui32PWMOut == PWM_OUT_2) || (ui32PWMOut == PWM_OUT_3) ||
|
||
|
(ui32PWMOut == PWM_OUT_4) || (ui32PWMOut == PWM_OUT_5) ||
|
||
|
(ui32PWMOut == PWM_OUT_6) || (ui32PWMOut == PWM_OUT_7));
|
||
|
}
|
||
|
#endif
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Configures a PWM generator.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32Gen is the PWM generator to configure. This parameter must be
|
||
|
//! one of \b PWM_GEN_0, \b PWM_GEN_1, \b PWM_GEN_2, or \b PWM_GEN_3.
|
||
|
//! \param ui32Config is the configuration for the PWM generator.
|
||
|
//!
|
||
|
//! This function is used to set the mode of operation for a PWM generator.
|
||
|
//! The counting mode, synchronization mode, and debug behavior are all
|
||
|
//! configured. After configuration, the generator is left in the disabled
|
||
|
//! state.
|
||
|
//!
|
||
|
//! A PWM generator can count in two different modes: count down mode or count
|
||
|
//! up/down mode. In count down mode, it counts from a value down to zero,
|
||
|
//! and then resets to the preset value, producing left-aligned PWM
|
||
|
//! signals (that is, the rising edge of the two PWM signals produced by the
|
||
|
//! generator occur at the same time). In count up/down mode, it counts up
|
||
|
//! from zero to the preset value, counts back down to zero, and then repeats
|
||
|
//! the process, producing center-aligned PWM signals (that is,
|
||
|
//! the middle of the high/low period of the PWM signals produced by the
|
||
|
//! generator occurs at the same time).
|
||
|
//!
|
||
|
//! When the PWM generator parameters (period and pulse width) are modified,
|
||
|
//! their effect on the output PWM signals can be delayed. In synchronous
|
||
|
//! mode, the parameter updates are not applied until a synchronization event
|
||
|
//! occurs. This mode allows multiple parameters to be modified and take
|
||
|
//! effect simultaneously, instead of one at a time. Additionally, parameters
|
||
|
//! to multiple PWM generators in synchronous mode can be updated
|
||
|
//! simultaneously, allowing them to be treated as if they were a unified
|
||
|
//! generator. In non-synchronous mode, the parameter updates are not delayed
|
||
|
//! until a synchronization event. In either mode, the parameter updates only
|
||
|
//! occur when the counter is at zero to help prevent oddly formed PWM signals
|
||
|
//! during the update (that is, a PWM pulse that is too short or too long).
|
||
|
//!
|
||
|
//! The PWM generator can either pause or continue running when the processor
|
||
|
//! is stopped via the debugger. If configured to pause, it continues to
|
||
|
//! count until it reaches zero, at which point it pauses until the
|
||
|
//! processor is restarted. If configured to continue running, it keeps
|
||
|
//! counting as if nothing had happened.
|
||
|
//!
|
||
|
//! The \e ui32Config parameter contains the desired configuration. It is the
|
||
|
//! logical OR of the following:
|
||
|
//!
|
||
|
//! - \b PWM_GEN_MODE_DOWN or \b PWM_GEN_MODE_UP_DOWN to specify the counting
|
||
|
//! mode
|
||
|
//! - \b PWM_GEN_MODE_SYNC or \b PWM_GEN_MODE_NO_SYNC to specify the counter
|
||
|
//! load and comparator update synchronization mode
|
||
|
//! - \b PWM_GEN_MODE_DBG_RUN or \b PWM_GEN_MODE_DBG_STOP to specify the debug
|
||
|
//! behavior
|
||
|
//! - \b PWM_GEN_MODE_GEN_NO_SYNC, \b PWM_GEN_MODE_GEN_SYNC_LOCAL, or
|
||
|
//! \b PWM_GEN_MODE_GEN_SYNC_GLOBAL to specify the update synchronization
|
||
|
//! mode for generator counting mode changes
|
||
|
//! - \b PWM_GEN_MODE_DB_NO_SYNC, \b PWM_GEN_MODE_DB_SYNC_LOCAL, or
|
||
|
//! \b PWM_GEN_MODE_DB_SYNC_GLOBAL to specify the deadband parameter
|
||
|
//! synchronization mode
|
||
|
//! - \b PWM_GEN_MODE_FAULT_LATCHED or \b PWM_GEN_MODE_FAULT_UNLATCHED to
|
||
|
//! specify whether fault conditions are latched or not
|
||
|
//! - \b PWM_GEN_MODE_FAULT_MINPER or \b PWM_GEN_MODE_FAULT_NO_MINPER to
|
||
|
//! specify whether minimum fault period support is required
|
||
|
//! - \b PWM_GEN_MODE_FAULT_EXT or \b PWM_GEN_MODE_FAULT_LEGACY to specify
|
||
|
//! whether extended fault source selection support is enabled or not
|
||
|
//!
|
||
|
//! Setting \b PWM_GEN_MODE_FAULT_MINPER allows an application to set the
|
||
|
//! minimum duration of a PWM fault signal. Faults are signaled for at
|
||
|
//! least this time even if the external fault pin deasserts earlier. Care
|
||
|
//! should be taken when using this mode because during the fault signal
|
||
|
//! period, the fault interrupt from the PWM generator remains asserted. The
|
||
|
//! fault interrupt handler may, therefore, reenter immediately if it exits
|
||
|
//! prior to expiration of the fault timer.
|
||
|
//!
|
||
|
//! \note Changes to the counter mode affect the period of the PWM signals
|
||
|
//! produced. PWMGenPeriodSet() and PWMPulseWidthSet() should be called after
|
||
|
//! any changes to the counter mode of a generator.
|
||
|
//!
|
||
|
//! \return None.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
void
|
||
|
PWMGenConfigure(uint32_t ui32Base, uint32_t ui32Gen,
|
||
|
uint32_t ui32Config)
|
||
|
{
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT(_PWMGenValid(ui32Gen));
|
||
|
|
||
|
//
|
||
|
// Compute the generator's base address.
|
||
|
//
|
||
|
ui32Gen = PWM_GEN_BADDR(ui32Base, ui32Gen);
|
||
|
|
||
|
//
|
||
|
// Change the global configuration of the generator.
|
||
|
//
|
||
|
HWREG(ui32Gen + PWM_O_X_CTL) = ((HWREG(ui32Gen + PWM_O_X_CTL) &
|
||
|
~(PWM_X_CTL_MODE | PWM_X_CTL_DEBUG |
|
||
|
PWM_X_CTL_LATCH | PWM_X_CTL_MINFLTPER |
|
||
|
PWM_X_CTL_FLTSRC |
|
||
|
PWM_X_CTL_DBFALLUPD_M |
|
||
|
PWM_X_CTL_DBRISEUPD_M |
|
||
|
PWM_X_CTL_DBCTLUPD_M |
|
||
|
PWM_X_CTL_GENBUPD_M |
|
||
|
PWM_X_CTL_GENAUPD_M |
|
||
|
PWM_X_CTL_LOADUPD | PWM_X_CTL_CMPAUPD |
|
||
|
PWM_X_CTL_CMPBUPD)) | ui32Config);
|
||
|
|
||
|
//
|
||
|
// Set the individual PWM generator controls.
|
||
|
//
|
||
|
if (ui32Config & PWM_X_CTL_MODE)
|
||
|
{
|
||
|
//
|
||
|
// In up/down count mode, set the signal high on up count comparison
|
||
|
// and low on down count comparison (that is, center align the
|
||
|
// signals).
|
||
|
//
|
||
|
HWREG(ui32Gen + PWM_O_X_GENA) = (PWM_X_GENA_ACTCMPAU_ONE |
|
||
|
PWM_X_GENA_ACTCMPAD_ZERO);
|
||
|
HWREG(ui32Gen + PWM_O_X_GENB) = (PWM_X_GENB_ACTCMPBU_ONE |
|
||
|
PWM_X_GENB_ACTCMPBD_ZERO);
|
||
|
}
|
||
|
else
|
||
|
{
|
||
|
//
|
||
|
// In down count mode, set the signal high on load and low on count
|
||
|
// comparison (that is, left align the signals).
|
||
|
//
|
||
|
HWREG(ui32Gen + PWM_O_X_GENA) = (PWM_X_GENA_ACTLOAD_ONE |
|
||
|
PWM_X_GENA_ACTCMPAD_ZERO);
|
||
|
HWREG(ui32Gen + PWM_O_X_GENB) = (PWM_X_GENB_ACTLOAD_ONE |
|
||
|
PWM_X_GENB_ACTCMPBD_ZERO);
|
||
|
}
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Sets the period of a PWM generator.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32Gen is the PWM generator to be modified. This parameter must be
|
||
|
//! one of \b PWM_GEN_0, \b PWM_GEN_1, \b PWM_GEN_2, or \b PWM_GEN_3.
|
||
|
//! \param ui32Period specifies the period of PWM generator output, measured
|
||
|
//! in clock ticks.
|
||
|
//!
|
||
|
//! This function sets the period of the specified PWM generator block, where
|
||
|
//! the period of the generator block is defined as the number of PWM clock
|
||
|
//! ticks between pulses on the generator block zero signal.
|
||
|
//!
|
||
|
//! \note Any subsequent calls made to this function before an update occurs
|
||
|
//! cause the previous values to be overwritten.
|
||
|
//!
|
||
|
//! \return None.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
void
|
||
|
PWMGenPeriodSet(uint32_t ui32Base, uint32_t ui32Gen,
|
||
|
uint32_t ui32Period)
|
||
|
{
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT(_PWMGenValid(ui32Gen));
|
||
|
|
||
|
//
|
||
|
// Compute the generator's base address.
|
||
|
//
|
||
|
ui32Gen = PWM_GEN_BADDR(ui32Base, ui32Gen);
|
||
|
|
||
|
//
|
||
|
// Set the reload register based on the mode.
|
||
|
//
|
||
|
if (HWREG(ui32Gen + PWM_O_X_CTL) & PWM_X_CTL_MODE)
|
||
|
{
|
||
|
//
|
||
|
// In up/down count mode, set the reload register to half the requested
|
||
|
// period.
|
||
|
//
|
||
|
ASSERT((ui32Period / 2) < 65536);
|
||
|
HWREG(ui32Gen + PWM_O_X_LOAD) = ui32Period / 2;
|
||
|
}
|
||
|
else
|
||
|
{
|
||
|
//
|
||
|
// In down count mode, set the reload register to the requested period
|
||
|
// minus one.
|
||
|
//
|
||
|
ASSERT((ui32Period <= 65536) && (ui32Period != 0));
|
||
|
HWREG(ui32Gen + PWM_O_X_LOAD) = ui32Period - 1;
|
||
|
}
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Gets the period of a PWM generator block.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32Gen is the PWM generator to query. This parameter must be one
|
||
|
//! of \b PWM_GEN_0, \b PWM_GEN_1, \b PWM_GEN_2, or \b PWM_GEN_3.
|
||
|
//!
|
||
|
//! This function gets the period of the specified PWM generator block. The
|
||
|
//! period of the generator block is defined as the number of PWM clock ticks
|
||
|
//! between pulses on the generator block zero signal.
|
||
|
//!
|
||
|
//! If the update of the counter for the specified PWM generator has yet
|
||
|
//! to be completed, the value returned may not be the active period. The
|
||
|
//! value returned is the programmed period, measured in PWM clock ticks.
|
||
|
//!
|
||
|
//! \return Returns the programmed period of the specified generator block
|
||
|
//! in PWM clock ticks.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
uint32_t
|
||
|
PWMGenPeriodGet(uint32_t ui32Base, uint32_t ui32Gen)
|
||
|
{
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT(_PWMGenValid(ui32Gen));
|
||
|
|
||
|
//
|
||
|
// Compute the generator's base address.
|
||
|
//
|
||
|
ui32Gen = PWM_GEN_BADDR(ui32Base, ui32Gen);
|
||
|
|
||
|
//
|
||
|
// Figure out the counter mode.
|
||
|
//
|
||
|
if (HWREG(ui32Gen + PWM_O_X_CTL) & PWM_X_CTL_MODE)
|
||
|
{
|
||
|
//
|
||
|
// The period is twice the reload register value.
|
||
|
//
|
||
|
return (HWREG(ui32Gen + PWM_O_X_LOAD) * 2);
|
||
|
}
|
||
|
else
|
||
|
{
|
||
|
//
|
||
|
// The period is the reload register value plus one.
|
||
|
//
|
||
|
return (HWREG(ui32Gen + PWM_O_X_LOAD) + 1);
|
||
|
}
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Enables the timer/counter for a PWM generator block.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32Gen is the PWM generator to be enabled. This parameter must be
|
||
|
//! one of \b PWM_GEN_0, \b PWM_GEN_1, \b PWM_GEN_2, or \b PWM_GEN_3.
|
||
|
//!
|
||
|
//! This function allows the PWM clock to drive the timer/counter for the
|
||
|
//! specified generator block.
|
||
|
//!
|
||
|
//! \return None.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
void
|
||
|
PWMGenEnable(uint32_t ui32Base, uint32_t ui32Gen)
|
||
|
{
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT(_PWMGenValid(ui32Gen));
|
||
|
|
||
|
//
|
||
|
// Enable the PWM generator.
|
||
|
//
|
||
|
HWREG(PWM_GEN_BADDR(ui32Base, ui32Gen) + PWM_O_X_CTL) |= PWM_X_CTL_ENABLE;
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Disables the timer/counter for a PWM generator block.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32Gen is the PWM generator to be disabled. This parameter must be
|
||
|
//! one of \b PWM_GEN_0, \b PWM_GEN_1, \b PWM_GEN_2, or \b PWM_GEN_3.
|
||
|
//!
|
||
|
//! This function blocks the PWM clock from driving the timer/counter for the
|
||
|
//! specified generator block.
|
||
|
//!
|
||
|
//! \return None.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
void
|
||
|
PWMGenDisable(uint32_t ui32Base, uint32_t ui32Gen)
|
||
|
{
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT(_PWMGenValid(ui32Gen));
|
||
|
|
||
|
//
|
||
|
// Disable the PWM generator.
|
||
|
//
|
||
|
HWREG(PWM_GEN_BADDR(ui32Base, ui32Gen) + PWM_O_X_CTL) &=
|
||
|
~(PWM_X_CTL_ENABLE);
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Sets the pulse width for the specified PWM output.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32PWMOut is the PWM output to modify. This parameter must be one
|
||
|
//! of \b PWM_OUT_0, \b PWM_OUT_1, \b PWM_OUT_2, \b PWM_OUT_3, \b PWM_OUT_4,
|
||
|
//! \b PWM_OUT_5, \b PWM_OUT_6, or \b PWM_OUT_7.
|
||
|
//! \param ui32Width specifies the width of the positive portion of the pulse.
|
||
|
//!
|
||
|
//! This function sets the pulse width for the specified PWM output, where the
|
||
|
//! pulse width is defined as the number of PWM clock ticks.
|
||
|
//!
|
||
|
//! \note Any subsequent calls made to this function before an update occurs
|
||
|
//! cause the previous values to be overwritten.
|
||
|
//!
|
||
|
//! \return None.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
void
|
||
|
PWMPulseWidthSet(uint32_t ui32Base, uint32_t ui32PWMOut,
|
||
|
uint32_t ui32Width)
|
||
|
{
|
||
|
uint32_t ui32GenBase, ui32Reg;
|
||
|
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT(_PWMOutValid(ui32PWMOut));
|
||
|
|
||
|
//
|
||
|
// Compute the generator's base address.
|
||
|
//
|
||
|
ui32GenBase = PWM_OUT_BADDR(ui32Base, ui32PWMOut);
|
||
|
|
||
|
//
|
||
|
// If the counter is in up/down count mode, divide the width by two.
|
||
|
//
|
||
|
if (HWREG(ui32GenBase + PWM_O_X_CTL) & PWM_X_CTL_MODE)
|
||
|
{
|
||
|
ui32Width /= 2;
|
||
|
}
|
||
|
|
||
|
//
|
||
|
// Get the period.
|
||
|
//
|
||
|
ui32Reg = HWREG(ui32GenBase + PWM_O_X_LOAD);
|
||
|
|
||
|
//
|
||
|
// Make sure the width is not too large.
|
||
|
//
|
||
|
ASSERT(ui32Width < ui32Reg);
|
||
|
|
||
|
//
|
||
|
// Compute the compare value.
|
||
|
//
|
||
|
ui32Reg = ui32Reg - ui32Width;
|
||
|
|
||
|
//
|
||
|
// Write to the appropriate registers.
|
||
|
//
|
||
|
if (PWM_IS_OUTPUT_ODD(ui32PWMOut))
|
||
|
{
|
||
|
HWREG(ui32GenBase + PWM_O_X_CMPB) = ui32Reg;
|
||
|
}
|
||
|
else
|
||
|
{
|
||
|
HWREG(ui32GenBase + PWM_O_X_CMPA) = ui32Reg;
|
||
|
}
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Gets the pulse width of a PWM output.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32PWMOut is the PWM output to query. This parameter must be one
|
||
|
//! of \b PWM_OUT_0, \b PWM_OUT_1, \b PWM_OUT_2, \b PWM_OUT_3, \b PWM_OUT_4,
|
||
|
//! \b PWM_OUT_5, \b PWM_OUT_6, or \b PWM_OUT_7.
|
||
|
//!
|
||
|
//! This function gets the currently programmed pulse width for the specified
|
||
|
//! PWM output. If the update of the comparator for the specified output has
|
||
|
//! yet to be completed, the value returned may not be the active pulse width.
|
||
|
//! The value returned is the programmed pulse width, measured in PWM clock
|
||
|
//! ticks.
|
||
|
//!
|
||
|
//! \return Returns the width of the pulse in PWM clock ticks.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
uint32_t
|
||
|
PWMPulseWidthGet(uint32_t ui32Base, uint32_t ui32PWMOut)
|
||
|
{
|
||
|
uint32_t ui32GenBase, ui32Reg, ui32Load;
|
||
|
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT(_PWMOutValid(ui32PWMOut));
|
||
|
|
||
|
//
|
||
|
// Compute the generator's base address.
|
||
|
//
|
||
|
ui32GenBase = PWM_OUT_BADDR(ui32Base, ui32PWMOut);
|
||
|
|
||
|
//
|
||
|
// Then compute the pulse width. If mode is UpDown, set
|
||
|
// width = (load - compare) * 2. Otherwise, set width = load - compare.
|
||
|
//
|
||
|
ui32Load = HWREG(ui32GenBase + PWM_O_X_LOAD);
|
||
|
if (PWM_IS_OUTPUT_ODD(ui32PWMOut))
|
||
|
{
|
||
|
ui32Reg = HWREG(ui32GenBase + PWM_O_X_CMPB);
|
||
|
}
|
||
|
else
|
||
|
{
|
||
|
ui32Reg = HWREG(ui32GenBase + PWM_O_X_CMPA);
|
||
|
}
|
||
|
ui32Reg = ui32Load - ui32Reg;
|
||
|
|
||
|
//
|
||
|
// If in up/down count mode, double the pulse width.
|
||
|
//
|
||
|
if (HWREG(ui32GenBase + PWM_O_X_CTL) & PWM_X_CTL_MODE)
|
||
|
{
|
||
|
ui32Reg = ui32Reg * 2;
|
||
|
}
|
||
|
|
||
|
//
|
||
|
// Return the pulse width.
|
||
|
//
|
||
|
return (ui32Reg);
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Enables the PWM dead band output and sets the dead band delays.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32Gen is the PWM generator to modify. This parameter must be one
|
||
|
//! of \b PWM_GEN_0, \b PWM_GEN_1, \b PWM_GEN_2, or \b PWM_GEN_3.
|
||
|
//! \param ui16Rise specifies the width of delay from the rising edge.
|
||
|
//! \param ui16Fall specifies the width of delay from the falling edge.
|
||
|
//!
|
||
|
//! This function sets the dead bands for the specified PWM generator, where
|
||
|
//! the dead bands are defined as the number of \b PWM clock ticks from the
|
||
|
//! rising or falling edge of the generator's \b OutA signal. Note that this
|
||
|
//! function causes the coupling of \b OutB to \b OutA.
|
||
|
//!
|
||
|
//! \return None.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
void
|
||
|
PWMDeadBandEnable(uint32_t ui32Base, uint32_t ui32Gen,
|
||
|
uint16_t ui16Rise, uint16_t ui16Fall)
|
||
|
{
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT(_PWMGenValid(ui32Gen));
|
||
|
ASSERT(ui16Rise < 4096);
|
||
|
ASSERT(ui16Fall < 4096);
|
||
|
|
||
|
//
|
||
|
// Compute the generator's base address.
|
||
|
//
|
||
|
ui32Gen = PWM_GEN_BADDR(ui32Base, ui32Gen);
|
||
|
|
||
|
//
|
||
|
// Write the dead band delay values.
|
||
|
//
|
||
|
HWREG(ui32Gen + PWM_O_X_DBRISE) = ui16Rise;
|
||
|
HWREG(ui32Gen + PWM_O_X_DBFALL) = ui16Fall;
|
||
|
|
||
|
//
|
||
|
// Enable the deadband functionality.
|
||
|
//
|
||
|
HWREG(ui32Gen + PWM_O_X_DBCTL) |= PWM_X_DBCTL_ENABLE;
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Disables the PWM dead band output.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32Gen is the PWM generator to modify. This parameter must be one
|
||
|
//! of \b PWM_GEN_0, \b PWM_GEN_1, \b PWM_GEN_2, or \b PWM_GEN_3.
|
||
|
//!
|
||
|
//! This function disables the dead band mode for the specified PWM generator.
|
||
|
//! Doing so decouples the \b OutA and \b OutB signals.
|
||
|
//!
|
||
|
//! \return None.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
void
|
||
|
PWMDeadBandDisable(uint32_t ui32Base, uint32_t ui32Gen)
|
||
|
{
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT(_PWMGenValid(ui32Gen));
|
||
|
|
||
|
//
|
||
|
// Disable the deadband functionality.
|
||
|
//
|
||
|
HWREG(PWM_GEN_BADDR(ui32Base, ui32Gen) + PWM_O_X_DBCTL) &=
|
||
|
~(PWM_X_DBCTL_ENABLE);
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Synchronizes all pending updates.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32GenBits are the PWM generator blocks to be updated. This
|
||
|
//! parameter must be the logical OR of any of \b PWM_GEN_0_BIT,
|
||
|
//! \b PWM_GEN_1_BIT, \b PWM_GEN_2_BIT, or \b PWM_GEN_3_BIT.
|
||
|
//!
|
||
|
//! For the selected PWM generators, this function causes all queued updates to
|
||
|
//! the period or pulse width to be applied the next time the corresponding
|
||
|
//! counter becomes zero.
|
||
|
//!
|
||
|
//! \return None.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
void
|
||
|
PWMSyncUpdate(uint32_t ui32Base, uint32_t ui32GenBits)
|
||
|
{
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT(!(ui32GenBits & ~(PWM_GEN_0_BIT | PWM_GEN_1_BIT | PWM_GEN_2_BIT |
|
||
|
PWM_GEN_3_BIT)));
|
||
|
|
||
|
//
|
||
|
// Synchronize pending PWM register changes.
|
||
|
//
|
||
|
HWREG(ui32Base + PWM_O_CTL) = ui32GenBits;
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Synchronizes the counters in one or multiple PWM generator blocks.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32GenBits are the PWM generator blocks to be synchronized. This
|
||
|
//! parameter must be the logical OR of any of \b PWM_GEN_0_BIT,
|
||
|
//! \b PWM_GEN_1_BIT, \b PWM_GEN_2_BIT, or \b PWM_GEN_3_BIT.
|
||
|
//!
|
||
|
//! For the selected PWM module, this function synchronizes the time base of
|
||
|
//! the generator blocks by causing the specified generator counters to be
|
||
|
//! reset to zero.
|
||
|
//!
|
||
|
//! \return None.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
void
|
||
|
PWMSyncTimeBase(uint32_t ui32Base, uint32_t ui32GenBits)
|
||
|
{
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT(!(ui32GenBits & ~(PWM_GEN_0_BIT | PWM_GEN_1_BIT | PWM_GEN_2_BIT |
|
||
|
PWM_GEN_3_BIT)));
|
||
|
|
||
|
//
|
||
|
// Synchronize the counters in the specified generators by writing to the
|
||
|
// module's synchronization register.
|
||
|
//
|
||
|
HWREG(ui32Base + PWM_O_SYNC) = ui32GenBits;
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Enables or disables PWM outputs.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32PWMOutBits are the PWM outputs to be modified. This parameter
|
||
|
//! must be the logical OR of any of \b PWM_OUT_0_BIT, \b PWM_OUT_1_BIT,
|
||
|
//! \b PWM_OUT_2_BIT, \b PWM_OUT_3_BIT, \b PWM_OUT_4_BIT, \b PWM_OUT_5_BIT,
|
||
|
//! \b PWM_OUT_6_BIT, or \b PWM_OUT_7_BIT.
|
||
|
//! \param bEnable determines if the signal is enabled or disabled.
|
||
|
//!
|
||
|
//! This function enables or disables the selected PWM outputs. The outputs
|
||
|
//! are selected using the parameter \e ui32PWMOutBits. The parameter \e
|
||
|
//! bEnable determines the state of the selected outputs. If \e bEnable is
|
||
|
//! \b true, then the selected PWM outputs are enabled, or placed in the active
|
||
|
//! state. If \e bEnable is \b false, then the selected outputs are disabled
|
||
|
//! or placed in the inactive state.
|
||
|
//!
|
||
|
//! \return None.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
void
|
||
|
PWMOutputState(uint32_t ui32Base, uint32_t ui32PWMOutBits,
|
||
|
bool bEnable)
|
||
|
{
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT(!(ui32PWMOutBits & ~(PWM_OUT_0_BIT | PWM_OUT_1_BIT | PWM_OUT_2_BIT |
|
||
|
PWM_OUT_3_BIT | PWM_OUT_4_BIT | PWM_OUT_5_BIT |
|
||
|
PWM_OUT_6_BIT | PWM_OUT_7_BIT)));
|
||
|
|
||
|
//
|
||
|
// Read the module's ENABLE output control register and set or clear the
|
||
|
// requested bits.
|
||
|
//
|
||
|
if (bEnable == true)
|
||
|
{
|
||
|
HWREG(ui32Base + PWM_O_ENABLE) |= ui32PWMOutBits;
|
||
|
}
|
||
|
else
|
||
|
{
|
||
|
HWREG(ui32Base + PWM_O_ENABLE) &= ~(ui32PWMOutBits);
|
||
|
}
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Selects the inversion mode for PWM outputs.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32PWMOutBits are the PWM outputs to be modified. This parameter
|
||
|
//! must be the logical OR of any of \b PWM_OUT_0_BIT, \b PWM_OUT_1_BIT,
|
||
|
//! \b PWM_OUT_2_BIT, \b PWM_OUT_3_BIT, \b PWM_OUT_4_BIT, \b PWM_OUT_5_BIT,
|
||
|
//! \b PWM_OUT_6_BIT, or \b PWM_OUT_7_BIT.
|
||
|
//! \param bInvert determines if the signal is inverted or passed through.
|
||
|
//!
|
||
|
//! This function is used to select the inversion mode for the selected PWM
|
||
|
//! outputs. The outputs are selected using the parameter \e ui32PWMOutBits.
|
||
|
//! The parameter \e bInvert determines the inversion mode for the selected
|
||
|
//! outputs. If \e bInvert is \b true, this function causes the specified
|
||
|
//! PWM output signals to be inverted or made active low. If \e bInvert is
|
||
|
//! \b false, the specified outputs are passed through as is or made active
|
||
|
//! high.
|
||
|
//!
|
||
|
//! \return None.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
void
|
||
|
PWMOutputInvert(uint32_t ui32Base, uint32_t ui32PWMOutBits,
|
||
|
bool bInvert)
|
||
|
{
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT(!(ui32PWMOutBits & ~(PWM_OUT_0_BIT | PWM_OUT_1_BIT | PWM_OUT_2_BIT |
|
||
|
PWM_OUT_3_BIT | PWM_OUT_4_BIT | PWM_OUT_5_BIT |
|
||
|
PWM_OUT_6_BIT | PWM_OUT_7_BIT)));
|
||
|
|
||
|
//
|
||
|
// Read the module's INVERT output control register and set or clear the
|
||
|
// requested bits.
|
||
|
//
|
||
|
if (bInvert == true)
|
||
|
{
|
||
|
HWREG(ui32Base + PWM_O_INVERT) |= ui32PWMOutBits;
|
||
|
}
|
||
|
else
|
||
|
{
|
||
|
HWREG(ui32Base + PWM_O_INVERT) &= ~(ui32PWMOutBits);
|
||
|
}
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Specifies the level of PWM outputs suppressed in response to a fault
|
||
|
//! condition.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32PWMOutBits are the PWM outputs to be modified. This parameter
|
||
|
//! must be the logical OR of any of \b PWM_OUT_0_BIT, \b PWM_OUT_1_BIT,
|
||
|
//! \b PWM_OUT_2_BIT, \b PWM_OUT_3_BIT, \b PWM_OUT_4_BIT, \b PWM_OUT_5_BIT,
|
||
|
//! \b PWM_OUT_6_BIT, or \b PWM_OUT_7_BIT.
|
||
|
//! \param bDriveHigh determines if the signal is driven high or low during an
|
||
|
//! active fault condition.
|
||
|
//!
|
||
|
//! This function determines whether a PWM output pin that is suppressed in
|
||
|
//! response to a fault condition is driven high or low. The affected outputs
|
||
|
//! are selected using the parameter \e ui32PWMOutBits. The parameter
|
||
|
//! \e bDriveHigh determines the output level for the pins identified by
|
||
|
//! \e ui32PWMOutBits. If \e bDriveHigh is \b true then the selected outputs
|
||
|
//! are driven high when a fault is detected. If it is \e false, the pins are
|
||
|
//! driven low.
|
||
|
//!
|
||
|
//! In a fault condition, pins which have not been configured to be suppressed
|
||
|
//! via a call to PWMOutputFault() are unaffected by this function.
|
||
|
//!
|
||
|
//! \return None.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
void
|
||
|
PWMOutputFaultLevel(uint32_t ui32Base, uint32_t ui32PWMOutBits,
|
||
|
bool bDriveHigh)
|
||
|
{
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT(!(ui32PWMOutBits & ~(PWM_OUT_0_BIT | PWM_OUT_1_BIT | PWM_OUT_2_BIT |
|
||
|
PWM_OUT_3_BIT | PWM_OUT_4_BIT | PWM_OUT_5_BIT |
|
||
|
PWM_OUT_6_BIT | PWM_OUT_7_BIT)));
|
||
|
|
||
|
//
|
||
|
// Read the module's FAULT output control register and set or clear the
|
||
|
// requested bits.
|
||
|
//
|
||
|
if (bDriveHigh == true)
|
||
|
{
|
||
|
HWREG(ui32Base + PWM_O_FAULTVAL) |= ui32PWMOutBits;
|
||
|
}
|
||
|
else
|
||
|
{
|
||
|
HWREG(ui32Base + PWM_O_FAULTVAL) &= ~(ui32PWMOutBits);
|
||
|
}
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Specifies the state of PWM outputs in response to a fault condition.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32PWMOutBits are the PWM outputs to be modified. This parameter
|
||
|
//! must be the logical OR of any of \b PWM_OUT_0_BIT, \b PWM_OUT_1_BIT,
|
||
|
//! \b PWM_OUT_2_BIT, \b PWM_OUT_3_BIT, \b PWM_OUT_4_BIT, \b PWM_OUT_5_BIT,
|
||
|
//! \b PWM_OUT_6_BIT, or \b PWM_OUT_7_BIT.
|
||
|
//! \param bFaultSuppress determines if the signal is suppressed or passed
|
||
|
//! through during an active fault condition.
|
||
|
//!
|
||
|
//! This function sets the fault handling characteristics of the selected PWM
|
||
|
//! outputs. The outputs are selected using the parameter \e ui32PWMOutBits.
|
||
|
//! The parameter \e bFaultSuppress determines the fault handling
|
||
|
//! characteristics for the selected outputs. If \e bFaultSuppress is \b true,
|
||
|
//! then the selected outputs are made inactive. If \e bFaultSuppress is
|
||
|
//! \b false, then the selected outputs are unaffected by the detected fault.
|
||
|
//!
|
||
|
//! The state the affected output pins are driven to can be configured with
|
||
|
//! PWMOutputFaultLevel(). If not configured, affected outputs are driven low
|
||
|
//! on a fault condition.
|
||
|
//!
|
||
|
//! \return None.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
void
|
||
|
PWMOutputFault(uint32_t ui32Base, uint32_t ui32PWMOutBits,
|
||
|
bool bFaultSuppress)
|
||
|
{
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT(!(ui32PWMOutBits & ~(PWM_OUT_0_BIT | PWM_OUT_1_BIT | PWM_OUT_2_BIT |
|
||
|
PWM_OUT_3_BIT | PWM_OUT_4_BIT | PWM_OUT_5_BIT |
|
||
|
PWM_OUT_6_BIT | PWM_OUT_7_BIT)));
|
||
|
|
||
|
//
|
||
|
// Read the module's FAULT output control register and set or clear the
|
||
|
// requested bits.
|
||
|
//
|
||
|
if (bFaultSuppress == true)
|
||
|
{
|
||
|
HWREG(ui32Base + PWM_O_FAULT) |= ui32PWMOutBits;
|
||
|
}
|
||
|
else
|
||
|
{
|
||
|
HWREG(ui32Base + PWM_O_FAULT) &= ~(ui32PWMOutBits);
|
||
|
}
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Gets the PWM generator interrupt number.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32Gen is the PWM generator in question. This parameter must be
|
||
|
//! one of \b PWM_GEN_0, \b PWM_GEN_1, \b PWM_GEN_2, or \b PWM_GEN_3.
|
||
|
//!
|
||
|
//! This function returns the interrupt number of the corresponding PWM
|
||
|
//! generator.
|
||
|
//!
|
||
|
//! \return Returns the interrupt number.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
static uint32_t
|
||
|
_PWMGenIntNumberGet(uint32_t ui32Base, uint32_t ui32Gen)
|
||
|
{
|
||
|
//
|
||
|
// Determine the generator and PWM module in question.
|
||
|
//
|
||
|
switch (ui32Base + ui32Gen)
|
||
|
{
|
||
|
//
|
||
|
// The first PWM generator in the first PWM module.
|
||
|
//
|
||
|
case PWM0_BASE + PWM_GEN_0:
|
||
|
{
|
||
|
return (INT_PWM0_0);
|
||
|
}
|
||
|
|
||
|
//
|
||
|
// The second PWM generator in the first PWM module.
|
||
|
//
|
||
|
case PWM0_BASE + PWM_GEN_1:
|
||
|
{
|
||
|
return (INT_PWM0_1);
|
||
|
}
|
||
|
|
||
|
//
|
||
|
// The third PWM generator in the first PWM module.
|
||
|
//
|
||
|
case PWM0_BASE + PWM_GEN_2:
|
||
|
{
|
||
|
return (INT_PWM0_2);
|
||
|
}
|
||
|
|
||
|
//
|
||
|
// The fourth PWM generator in the first PWM module.
|
||
|
//
|
||
|
case PWM0_BASE + PWM_GEN_3:
|
||
|
{
|
||
|
return (INT_PWM0_3);
|
||
|
}
|
||
|
|
||
|
//
|
||
|
// An unknown PWM module/generator was specified.
|
||
|
//
|
||
|
default:
|
||
|
{
|
||
|
return (0);
|
||
|
}
|
||
|
}
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Registers an interrupt handler for the specified PWM generator block.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32Gen is the PWM generator in question. This parameter must be
|
||
|
//! one of \b PWM_GEN_0, \b PWM_GEN_1, \b PWM_GEN_2, or \b PWM_GEN_3.
|
||
|
//! \param pfnIntHandler is a pointer to the function to be called when the PWM
|
||
|
//! generator interrupt occurs.
|
||
|
//!
|
||
|
//! This function ensures that the interrupt handler specified by
|
||
|
//! \e pfnIntHandler is called when an interrupt is detected for the specified
|
||
|
//! PWM generator block. This function also enables the corresponding
|
||
|
//! PWM generator interrupt in the interrupt controller; individual generator
|
||
|
//! interrupts and interrupt sources must be enabled with PWMIntEnable() and
|
||
|
//! PWMGenIntTrigEnable().
|
||
|
//!
|
||
|
//! \sa IntRegister() for important information about registering interrupt
|
||
|
//! handlers.
|
||
|
//!
|
||
|
//! \return None.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
void
|
||
|
PWMGenIntRegister(uint32_t ui32Base, uint32_t ui32Gen,
|
||
|
void (*pfnIntHandler)(void))
|
||
|
{
|
||
|
uint32_t ui32Int;
|
||
|
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT(_PWMGenValid(ui32Gen));
|
||
|
|
||
|
//
|
||
|
// Get the interrupt number associated with the specified generator.
|
||
|
//
|
||
|
ui32Int = _PWMGenIntNumberGet(ui32Base, ui32Gen);
|
||
|
|
||
|
ASSERT(ui32Int != 0);
|
||
|
|
||
|
//
|
||
|
// Register the interrupt handler.
|
||
|
//
|
||
|
IntRegister(ui32Int, pfnIntHandler);
|
||
|
|
||
|
//
|
||
|
// Enable the PWMx interrupt.
|
||
|
//
|
||
|
IntEnable(ui32Int);
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Removes an interrupt handler for the specified PWM generator block.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32Gen is the PWM generator in question. This parameter must be
|
||
|
//! one of \b PWM_GEN_0, \b PWM_GEN_1, \b PWM_GEN_2, or \b PWM_GEN_3.
|
||
|
//!
|
||
|
//! This function unregisters the interrupt handler for the specified
|
||
|
//! PWM generator block. This function also disables the corresponding
|
||
|
//! PWM generator interrupt in the interrupt controller; individual generator
|
||
|
//! interrupts and interrupt sources must be disabled with PWMIntDisable() and
|
||
|
//! PWMGenIntTrigDisable().
|
||
|
//!
|
||
|
//! \sa IntRegister() for important information about registering interrupt
|
||
|
//! handlers.
|
||
|
//!
|
||
|
//! \return None.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
void
|
||
|
PWMGenIntUnregister(uint32_t ui32Base, uint32_t ui32Gen)
|
||
|
{
|
||
|
uint32_t ui32Int;
|
||
|
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT(_PWMGenValid(ui32Gen));
|
||
|
|
||
|
//
|
||
|
// Get the interrupt number associated with the specified generator.
|
||
|
//
|
||
|
ui32Int = _PWMGenIntNumberGet(ui32Base, ui32Gen);
|
||
|
|
||
|
ASSERT(ui32Int != 0);
|
||
|
|
||
|
//
|
||
|
// Disable the PWMx interrupt.
|
||
|
//
|
||
|
IntDisable(ui32Int);
|
||
|
|
||
|
//
|
||
|
// Unregister the interrupt handler.
|
||
|
//
|
||
|
IntUnregister(ui32Int);
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Gets the PWM fault interrupt number.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//!
|
||
|
//! This function returns the fault interrupt number of the corresponding
|
||
|
//! PWM module.
|
||
|
//!
|
||
|
//! \return Returns the interrupt number.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
static uint32_t
|
||
|
_PWMFaultIntNumberGet(uint32_t ui32Base)
|
||
|
{
|
||
|
//
|
||
|
// Return the fault interrupt number.
|
||
|
//
|
||
|
return ((ui32Base == PWM0_BASE) ? INT_PWM0_FAULT : 0);
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Registers an interrupt handler for a fault condition detected in a PWM
|
||
|
//! module.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param pfnIntHandler is a pointer to the function to be called when the PWM
|
||
|
//! fault interrupt occurs.
|
||
|
//!
|
||
|
//! This function ensures that the interrupt handler specified by
|
||
|
//! \e pfnIntHandler is called when a fault interrupt is detected for the
|
||
|
//! selected PWM module. This function also enables the PWM fault
|
||
|
//! interrupt in the NVIC; the PWM fault interrupt must also be enabled at the
|
||
|
//! module level using PWMIntEnable().
|
||
|
//!
|
||
|
//! \sa IntRegister() for important information about registering interrupt
|
||
|
//! handlers.
|
||
|
//!
|
||
|
//! \return None.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
void
|
||
|
PWMFaultIntRegister(uint32_t ui32Base, void (*pfnIntHandler)(void))
|
||
|
{
|
||
|
uint32_t ui32Int;
|
||
|
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
//
|
||
|
// Get the interrupt number associated with the specified module.
|
||
|
//
|
||
|
ui32Int = _PWMFaultIntNumberGet(ui32Base);
|
||
|
|
||
|
ASSERT(ui32Int != 0);
|
||
|
|
||
|
//
|
||
|
// Register the interrupt handler, returning an error if one occurs.
|
||
|
//
|
||
|
IntRegister(ui32Int, pfnIntHandler);
|
||
|
|
||
|
//
|
||
|
// Enable the PWM fault interrupt.
|
||
|
//
|
||
|
IntEnable(ui32Int);
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Removes the PWM fault condition interrupt handler.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//!
|
||
|
//! This function removes the interrupt handler for a PWM fault interrupt
|
||
|
//! from the selected PWM module. This function also disables the PWM
|
||
|
//! fault interrupt in the NVIC; the PWM fault interrupt must also be disabled
|
||
|
//! at the module level using PWMIntDisable().
|
||
|
//!
|
||
|
//! \sa IntRegister() for important information about registering interrupt
|
||
|
//! handlers.
|
||
|
//!
|
||
|
//! \return None.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
void
|
||
|
PWMFaultIntUnregister(uint32_t ui32Base)
|
||
|
{
|
||
|
uint32_t ui32Int;
|
||
|
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
//
|
||
|
// Get the interrupt number associated with the specified module.
|
||
|
//
|
||
|
ui32Int = _PWMFaultIntNumberGet(ui32Base);
|
||
|
|
||
|
ASSERT(ui32Int != 0);
|
||
|
|
||
|
//
|
||
|
// Disable the PWM fault interrupt.
|
||
|
//
|
||
|
IntDisable(ui32Int);
|
||
|
|
||
|
//
|
||
|
// Unregister the interrupt handler, returning an error if one occurs.
|
||
|
//
|
||
|
IntUnregister(ui32Int);
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Enables interrupts and triggers for the specified PWM generator block.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32Gen is the PWM generator to have interrupts and triggers
|
||
|
//! enabled. This parameter must be one of \b PWM_GEN_0, \b PWM_GEN_1,
|
||
|
//! \b PWM_GEN_2, or \b PWM_GEN_3.
|
||
|
//! \param ui32IntTrig specifies the interrupts and triggers to be enabled.
|
||
|
//!
|
||
|
//! This function unmasks the specified interrupt(s) and trigger(s) by setting
|
||
|
//! the specified bits of the interrupt/trigger enable register for the
|
||
|
//! specified PWM generator. The \e ui32IntTrig parameter is the logical OR of
|
||
|
//! \b PWM_INT_CNT_ZERO, \b PWM_INT_CNT_LOAD, \b PWM_INT_CNT_AU,
|
||
|
//! \b PWM_INT_CNT_AD, \b PWM_INT_CNT_BU, \b PWM_INT_CNT_BD,
|
||
|
//! \b PWM_TR_CNT_ZERO, \b PWM_TR_CNT_LOAD, \b PWM_TR_CNT_AU, \b PWM_TR_CNT_AD,
|
||
|
//! \b PWM_TR_CNT_BU, or \b PWM_TR_CNT_BD.
|
||
|
//!
|
||
|
//! \return None.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
void
|
||
|
PWMGenIntTrigEnable(uint32_t ui32Base, uint32_t ui32Gen,
|
||
|
uint32_t ui32IntTrig)
|
||
|
{
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT(_PWMGenValid(ui32Gen));
|
||
|
ASSERT((ui32IntTrig & ~(PWM_INT_CNT_ZERO | PWM_INT_CNT_LOAD |
|
||
|
PWM_INT_CNT_AU | PWM_INT_CNT_AD | PWM_INT_CNT_BU |
|
||
|
PWM_INT_CNT_BD | PWM_TR_CNT_ZERO |
|
||
|
PWM_TR_CNT_LOAD | PWM_TR_CNT_AU | PWM_TR_CNT_AD |
|
||
|
PWM_TR_CNT_BU | PWM_TR_CNT_BD)) == 0);
|
||
|
|
||
|
//
|
||
|
// Enable the specified interrupts/triggers.
|
||
|
//
|
||
|
HWREG(PWM_GEN_BADDR(ui32Base, ui32Gen) + PWM_O_X_INTEN) |= ui32IntTrig;
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Disables interrupts for the specified PWM generator block.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32Gen is the PWM generator to have interrupts and triggers
|
||
|
//! disabled. This parameter must be one of \b PWM_GEN_0, \b PWM_GEN_1,
|
||
|
//! \b PWM_GEN_2, or \b PWM_GEN_3.
|
||
|
//! \param ui32IntTrig specifies the interrupts and triggers to be disabled.
|
||
|
//!
|
||
|
//! This function masks the specified interrupt(s) and trigger(s) by clearing
|
||
|
//! the specified bits of the interrupt/trigger enable register for the
|
||
|
//! specified PWM generator. The \e ui32IntTrig parameter is the logical OR of
|
||
|
//! \b PWM_INT_CNT_ZERO, \b PWM_INT_CNT_LOAD, \b PWM_INT_CNT_AU,
|
||
|
//! \b PWM_INT_CNT_AD, \b PWM_INT_CNT_BU, \b PWM_INT_CNT_BD,
|
||
|
//! \b PWM_TR_CNT_ZERO, \b PWM_TR_CNT_LOAD, \b PWM_TR_CNT_AU, \b PWM_TR_CNT_AD,
|
||
|
//! \b PWM_TR_CNT_BU, or \b PWM_TR_CNT_BD.
|
||
|
//!
|
||
|
//! \return None.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
void
|
||
|
PWMGenIntTrigDisable(uint32_t ui32Base, uint32_t ui32Gen,
|
||
|
uint32_t ui32IntTrig)
|
||
|
{
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT(_PWMGenValid(ui32Gen));
|
||
|
ASSERT((ui32IntTrig & ~(PWM_INT_CNT_ZERO | PWM_INT_CNT_LOAD |
|
||
|
PWM_INT_CNT_AU | PWM_INT_CNT_AD | PWM_INT_CNT_BU |
|
||
|
PWM_INT_CNT_BD | PWM_TR_CNT_ZERO |
|
||
|
PWM_TR_CNT_LOAD | PWM_TR_CNT_AU | PWM_TR_CNT_AD |
|
||
|
PWM_TR_CNT_BU | PWM_TR_CNT_BD)) == 0);
|
||
|
|
||
|
//
|
||
|
// Disable the specified interrupts/triggers.
|
||
|
//
|
||
|
HWREG(PWM_GEN_BADDR(ui32Base, ui32Gen) + PWM_O_X_INTEN) &= ~(ui32IntTrig);
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Gets interrupt status for the specified PWM generator block.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32Gen is the PWM generator to query. This parameter must be one
|
||
|
//! of \b PWM_GEN_0, \b PWM_GEN_1, \b PWM_GEN_2, or \b PWM_GEN_3.
|
||
|
//! \param bMasked specifies whether masked or raw interrupt status is
|
||
|
//! returned.
|
||
|
//!
|
||
|
//! If \e bMasked is set as \b true, then the masked interrupt status is
|
||
|
//! returned; otherwise, the raw interrupt status is returned.
|
||
|
//!
|
||
|
//! \return Returns the contents of the interrupt status register or the
|
||
|
//! contents of the raw interrupt status register for the specified
|
||
|
//! PWM generator.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
uint32_t
|
||
|
PWMGenIntStatus(uint32_t ui32Base, uint32_t ui32Gen, bool bMasked)
|
||
|
{
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT(_PWMGenValid(ui32Gen));
|
||
|
|
||
|
//
|
||
|
// Compute the generator's base address.
|
||
|
//
|
||
|
ui32Gen = PWM_GEN_BADDR(ui32Base, ui32Gen);
|
||
|
|
||
|
//
|
||
|
// Read and return the specified generator's raw or enabled interrupt
|
||
|
// status.
|
||
|
//
|
||
|
if (bMasked == true)
|
||
|
{
|
||
|
return (HWREG(ui32Gen + PWM_O_X_ISC));
|
||
|
}
|
||
|
else
|
||
|
{
|
||
|
return (HWREG(ui32Gen + PWM_O_X_RIS));
|
||
|
}
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Clears the specified interrupt(s) for the specified PWM generator block.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32Gen is the PWM generator to query. This parameter must be one
|
||
|
//! of \b PWM_GEN_0, \b PWM_GEN_1, \b PWM_GEN_2, or \b PWM_GEN_3.
|
||
|
//! \param ui32Ints specifies the interrupts to be cleared.
|
||
|
//!
|
||
|
//! This function clears the specified interrupt(s) by writing a 1 to the
|
||
|
//! specified bits of the interrupt status register for the specified PWM
|
||
|
//! generator. The \e ui32Ints parameter is the logical OR of
|
||
|
//! \b PWM_INT_CNT_ZERO, \b PWM_INT_CNT_LOAD, \b PWM_INT_CNT_AU,
|
||
|
//! \b PWM_INT_CNT_AD, \b PWM_INT_CNT_BU, or \b PWM_INT_CNT_BD.
|
||
|
//!
|
||
|
//! \note Because there is a write buffer in the Cortex-M processor, it may
|
||
|
//! take several clock cycles before the interrupt source is actually cleared.
|
||
|
//! Therefore, it is recommended that the interrupt source be cleared early in
|
||
|
//! the interrupt handler (as opposed to the very last action) to avoid
|
||
|
//! returning from the interrupt handler before the interrupt source is
|
||
|
//! actually cleared. Failure to do so may result in the interrupt handler
|
||
|
//! being immediately reentered (because the interrupt controller still sees
|
||
|
//! the interrupt source asserted).
|
||
|
//!
|
||
|
//! \return None.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
void
|
||
|
PWMGenIntClear(uint32_t ui32Base, uint32_t ui32Gen, uint32_t ui32Ints)
|
||
|
{
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT(_PWMGenValid(ui32Gen));
|
||
|
ASSERT((ui32Ints &
|
||
|
~(PWM_INT_CNT_ZERO | PWM_INT_CNT_LOAD | PWM_INT_CNT_AU |
|
||
|
PWM_INT_CNT_AD | PWM_INT_CNT_BU | PWM_INT_CNT_BD)) == 0);
|
||
|
|
||
|
//
|
||
|
// Clear the requested interrupts by writing ones to the specified bit
|
||
|
// of the module's interrupt enable register.
|
||
|
//
|
||
|
HWREG(PWM_GEN_BADDR(ui32Base, ui32Gen) + PWM_O_X_ISC) = ui32Ints;
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Enables generator and fault interrupts for a PWM module.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32GenFault contains the interrupts to be enabled. This parameter
|
||
|
//! must be a logical OR of any of \b PWM_INT_GEN_0, \b PWM_INT_GEN_1,
|
||
|
//! \b PWM_INT_GEN_2, \b PWM_INT_GEN_3, \b PWM_INT_FAULT0, \b PWM_INT_FAULT1,
|
||
|
//! \b PWM_INT_FAULT2, or \b PWM_INT_FAULT3.
|
||
|
//!
|
||
|
//! This function unmasks the specified interrupt(s) by setting the specified
|
||
|
//! bits of the interrupt enable register for the selected PWM module.
|
||
|
//!
|
||
|
//! \return None.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
void
|
||
|
PWMIntEnable(uint32_t ui32Base, uint32_t ui32GenFault)
|
||
|
{
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT((ui32GenFault & ~(PWM_INT_GEN_0 | PWM_INT_GEN_1 | PWM_INT_GEN_2 |
|
||
|
PWM_INT_GEN_3 | PWM_INT_FAULT0 | PWM_INT_FAULT1 |
|
||
|
PWM_INT_FAULT2 | PWM_INT_FAULT3)) == 0);
|
||
|
|
||
|
//
|
||
|
// Read the module's interrupt enable register and enable interrupts
|
||
|
// for the specified PWM generators.
|
||
|
//
|
||
|
HWREG(ui32Base + PWM_O_INTEN) |= ui32GenFault;
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Disables generator and fault interrupts for a PWM module.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32GenFault contains the interrupts to be disabled. This parameter
|
||
|
//! must be a logical OR of any of \b PWM_INT_GEN_0, \b PWM_INT_GEN_1,
|
||
|
//! \b PWM_INT_GEN_2, \b PWM_INT_GEN_3, \b PWM_INT_FAULT0, \b PWM_INT_FAULT1,
|
||
|
//! \b PWM_INT_FAULT2, or \b PWM_INT_FAULT3.
|
||
|
//!
|
||
|
//! This function masks the specified interrupt(s) by clearing the specified
|
||
|
//! bits of the interrupt enable register for the selected PWM module.
|
||
|
//!
|
||
|
//! \return None.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
void
|
||
|
PWMIntDisable(uint32_t ui32Base, uint32_t ui32GenFault)
|
||
|
{
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT((ui32GenFault & ~(PWM_INT_GEN_0 | PWM_INT_GEN_1 | PWM_INT_GEN_2 |
|
||
|
PWM_INT_GEN_3 | PWM_INT_FAULT0 | PWM_INT_FAULT1 |
|
||
|
PWM_INT_FAULT2 | PWM_INT_FAULT3)) == 0);
|
||
|
|
||
|
//
|
||
|
// Read the module's interrupt enable register and disable interrupts
|
||
|
// for the specified PWM generators.
|
||
|
//
|
||
|
HWREG(ui32Base + PWM_O_INTEN) &= ~(ui32GenFault);
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Gets the interrupt status for a PWM module.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param bMasked specifies whether masked or raw interrupt status is
|
||
|
//! returned.
|
||
|
//!
|
||
|
//! If \e bMasked is set as \b true, then the masked interrupt status is
|
||
|
//! returned; otherwise, the raw interrupt status is returned.
|
||
|
//!
|
||
|
//! \return The current interrupt status, enumerated as a bit field of
|
||
|
//! \b PWM_INT_GEN_0, \b PWM_INT_GEN_1, \b PWM_INT_GEN_2, \b PWM_INT_GEN_3,
|
||
|
//! \b PWM_INT_FAULT0, \b PWM_INT_FAULT1, \b PWM_INT_FAULT2, and
|
||
|
//! \b PWM_INT_FAULT3.
|
||
|
//!
|
||
|
//*****************************************************************************
|
||
|
uint32_t
|
||
|
PWMIntStatus(uint32_t ui32Base, bool bMasked)
|
||
|
{
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
|
||
|
//
|
||
|
// Read and return either the module's raw or enabled interrupt status.
|
||
|
//
|
||
|
if (bMasked == true)
|
||
|
{
|
||
|
return (HWREG(ui32Base + PWM_O_ISC));
|
||
|
}
|
||
|
else
|
||
|
{
|
||
|
return (HWREG(ui32Base + PWM_O_RIS));
|
||
|
}
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Clears the fault interrupt for a PWM module.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32FaultInts specifies the fault interrupts to clear.
|
||
|
//!
|
||
|
//! This function clears one or more fault interrupts by writing to the
|
||
|
//! appropriate bit of the PWM interrupt status register. The parameter
|
||
|
//! \e ui32FaultInts must be the logical OR of any of \b PWM_INT_FAULT0,
|
||
|
//! \b PWM_INT_FAULT1, \b PWM_INT_FAULT2, or \b PWM_INT_FAULT3.
|
||
|
//!
|
||
|
//! The fault interrupts are derived by performing a logical OR of each of the
|
||
|
//! configured fault trigger signals for a given generator. Therefore, these
|
||
|
//! interrupts are not directly related to the four possible FAULTn inputs to
|
||
|
//! the device but indicate that a fault has been signaled to one of the four
|
||
|
//! possible PWM generators.
|
||
|
//!
|
||
|
//! \note Because there is a write buffer in the Cortex-M processor, it may
|
||
|
//! take several clock cycles before the interrupt source is actually cleared.
|
||
|
//! Therefore, it is recommended that the interrupt source be cleared early in
|
||
|
//! the interrupt handler (as opposed to the very last action) to avoid
|
||
|
//! returning from the interrupt handler before the interrupt source is
|
||
|
//! actually cleared. Failure to do so may result in the interrupt handler
|
||
|
//! being immediately reentered (because the interrupt controller still sees
|
||
|
//! the interrupt source asserted).
|
||
|
//!
|
||
|
//! \return None.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
void
|
||
|
PWMFaultIntClearExt(uint32_t ui32Base, uint32_t ui32FaultInts)
|
||
|
{
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT((ui32FaultInts & ~(PWM_INT_FAULT0 | PWM_INT_FAULT1 |
|
||
|
PWM_INT_FAULT2 | PWM_INT_FAULT3)) == 0);
|
||
|
|
||
|
//
|
||
|
// Clear the supplied fault bits.
|
||
|
//
|
||
|
HWREG(ui32Base + PWM_O_ISC) = ui32FaultInts;
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Configures the minimum fault period and fault pin senses for a given
|
||
|
//! PWM generator.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32Gen is the PWM generator for which fault configuration is being
|
||
|
//! set. This function must be one of \b PWM_GEN_0, \b PWM_GEN_1,
|
||
|
//! \b PWM_GEN_2, or \b PWM_GEN_3.
|
||
|
//! \param ui32MinFaultPeriod is the minimum fault active period expressed in
|
||
|
//! PWM clock cycles.
|
||
|
//! \param ui32FaultSenses indicates which sense of each FAULT input should be
|
||
|
//! considered the ``asserted'' state. Valid values are logical OR
|
||
|
//! combinations of \b PWM_FAULTn_SENSE_HIGH and \b PWM_FAULTn_SENSE_LOW.
|
||
|
//!
|
||
|
//! This function configures the minimum fault period for a given generator
|
||
|
//! along with the sense of each of the 4 possible fault inputs. The minimum
|
||
|
//! fault period is expressed in PWM clock cycles and takes effect only if
|
||
|
//! PWMGenConfigure() is called with flag \b PWM_GEN_MODE_FAULT_PER set in the
|
||
|
//! \e ui32Config parameter. When a fault input is asserted, the minimum fault
|
||
|
//! period timer ensures that it remains asserted for at least the number of
|
||
|
//! clock cycles specified.
|
||
|
//!
|
||
|
//! \return None.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
void
|
||
|
PWMGenFaultConfigure(uint32_t ui32Base, uint32_t ui32Gen,
|
||
|
uint32_t ui32MinFaultPeriod,
|
||
|
uint32_t ui32FaultSenses)
|
||
|
{
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT(_PWMGenValid(ui32Gen));
|
||
|
ASSERT(ui32MinFaultPeriod < PWM_X_MINFLTPER_M);
|
||
|
ASSERT((ui32FaultSenses & ~(PWM_FAULT0_SENSE_HIGH | PWM_FAULT0_SENSE_LOW |
|
||
|
PWM_FAULT1_SENSE_HIGH | PWM_FAULT1_SENSE_LOW |
|
||
|
PWM_FAULT2_SENSE_HIGH | PWM_FAULT2_SENSE_LOW |
|
||
|
PWM_FAULT3_SENSE_HIGH |
|
||
|
PWM_FAULT3_SENSE_LOW)) == 0);
|
||
|
|
||
|
//
|
||
|
// Write the minimum fault period.
|
||
|
//
|
||
|
HWREG(PWM_GEN_BADDR(ui32Base, ui32Gen) + PWM_O_X_MINFLTPER) =
|
||
|
ui32MinFaultPeriod;
|
||
|
|
||
|
//
|
||
|
// Write the fault senses.
|
||
|
//
|
||
|
HWREG(PWM_GEN_EXT_BADDR(ui32Base, ui32Gen) + PWM_O_X_FLTSEN) =
|
||
|
ui32FaultSenses;
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Configures the set of fault triggers for a given PWM generator.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32Gen is the PWM generator for which fault triggers are being set.
|
||
|
//! This parameter must be one of \b PWM_GEN_0, \b PWM_GEN_1, \b PWM_GEN_2, or
|
||
|
//! \b PWM_GEN_3.
|
||
|
//! \param ui32Group indicates the subset of possible faults that are to be
|
||
|
//! configured. This parameter must be \b PWM_FAULT_GROUP_0 or
|
||
|
//! \b PWM_FAULT_GROUP_1.
|
||
|
//! \param ui32FaultTriggers defines the set of inputs that are to contribute
|
||
|
//! towards generation of the fault signal to the given PWM generator. For
|
||
|
//! \b PWM_FAULT_GROUP_0, this is the logical OR of \b PWM_FAULT_FAULT0,
|
||
|
//! \b PWM_FAULT_FAULT1, \b PWM_FAULT_FAULT2, or \b PWM_FAULT_FAULT3. For
|
||
|
//! \b PWM_FAULT_GROUP_1, this is the logical OR of \b PWM_FAULT_DCMP0,
|
||
|
//! \b PWM_FAULT_DCMP1, \b PWM_FAULT_DCMP2, \b PWM_FAULT_DCMP3,
|
||
|
//! \b PWM_FAULT_DCMP4, \b PWM_FAULT_DCMP5, \b PWM_FAULT_DCMP6, or
|
||
|
//! \b PWM_FAULT_DCMP7.
|
||
|
//!
|
||
|
//! This function allows selection of the set of fault inputs that is combined
|
||
|
//! to generate a fault condition to a given PWM generator. By default, all
|
||
|
//! generators use only FAULT0 (for backwards compatibility) but if
|
||
|
//! PWMGenConfigure() is called with flag \b PWM_GEN_MODE_FAULT_SRC in the
|
||
|
//! \e ui32Config parameter, extended fault handling is enabled and this
|
||
|
//! function must be called to configure the fault triggers.
|
||
|
//!
|
||
|
//! The fault signal to the PWM generator is generated by ORing together each
|
||
|
//! of the signals specified in the \e ui32FaultTriggers parameter after having
|
||
|
//! adjusted the sense of each FAULTn input based on the configuration
|
||
|
//! previously set using a call to PWMGenFaultConfigure().
|
||
|
//!
|
||
|
//! \return None.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
void
|
||
|
PWMGenFaultTriggerSet(uint32_t ui32Base, uint32_t ui32Gen,
|
||
|
uint32_t ui32Group, uint32_t ui32FaultTriggers)
|
||
|
{
|
||
|
//
|
||
|
// Check for valid parameters.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT(_PWMGenValid(ui32Gen));
|
||
|
ASSERT((ui32Group == PWM_FAULT_GROUP_0) ||
|
||
|
(ui32Group == PWM_FAULT_GROUP_1));
|
||
|
ASSERT((ui32Group == PWM_FAULT_GROUP_0) &&
|
||
|
((ui32FaultTriggers & ~(PWM_FAULT_FAULT0 | PWM_FAULT_FAULT1 |
|
||
|
PWM_FAULT_FAULT2 | PWM_FAULT_FAULT3)) ==
|
||
|
0));
|
||
|
ASSERT((ui32Group == PWM_FAULT_GROUP_1) &&
|
||
|
((ui32FaultTriggers & ~(PWM_FAULT_DCMP0 | PWM_FAULT_DCMP1 |
|
||
|
PWM_FAULT_DCMP2 | PWM_FAULT_DCMP3 |
|
||
|
PWM_FAULT_DCMP4 | PWM_FAULT_DCMP5 |
|
||
|
PWM_FAULT_DCMP6 | PWM_FAULT_DCMP7)) == 0));
|
||
|
|
||
|
//
|
||
|
// Write the fault triggers to the appropriate register.
|
||
|
//
|
||
|
if (ui32Group == PWM_FAULT_GROUP_0)
|
||
|
{
|
||
|
HWREG(PWM_GEN_BADDR(ui32Base, ui32Gen) + PWM_O_X_FLTSRC0) =
|
||
|
ui32FaultTriggers;
|
||
|
}
|
||
|
else
|
||
|
{
|
||
|
HWREG(PWM_GEN_BADDR(ui32Base, ui32Gen) + PWM_O_X_FLTSRC1) =
|
||
|
ui32FaultTriggers;
|
||
|
}
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Returns the set of fault triggers currently configured for a given PWM
|
||
|
//! generator.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32Gen is the PWM generator for which fault triggers are being
|
||
|
//! queried. This parameter must be one of \b PWM_GEN_0, \b PWM_GEN_1,
|
||
|
//! \b PWM_GEN_2, or \b PWM_GEN_3.
|
||
|
//! \param ui32Group indicates the subset of faults that are being queried.
|
||
|
//! This parameter must be \b PWM_FAULT_GROUP_0 or \b PWM_FAULT_GROUP_1.
|
||
|
//!
|
||
|
//! This function allows an application to query the current set of inputs that
|
||
|
//! contribute to the generation of a fault condition to a given PWM generator.
|
||
|
//!
|
||
|
//! \return Returns the current fault triggers configured for the fault group
|
||
|
//! provided. For \b PWM_FAULT_GROUP_0, the returned value is a logical OR of
|
||
|
//! \b PWM_FAULT_FAULT0, \b PWM_FAULT_FAULT1, \b PWM_FAULT_FAULT2, or
|
||
|
//! \b PWM_FAULT_FAULT3. For \b PWM_FAULT_GROUP_1, the return value is the
|
||
|
//! logical OR of \b PWM_FAULT_DCMP0, \b PWM_FAULT_DCMP1,
|
||
|
//! \b PWM_FAULT_DCMP2, \b PWM_FAULT_DCMP3, \b PWM_FAULT_DCMP4,
|
||
|
//! \b PWM_FAULT_DCMP5, \b PWM_FAULT_DCMP6, or \b PWM_FAULT_DCMP7.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
uint32_t
|
||
|
PWMGenFaultTriggerGet(uint32_t ui32Base, uint32_t ui32Gen,
|
||
|
uint32_t ui32Group)
|
||
|
{
|
||
|
//
|
||
|
// Check for valid parameters.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT(_PWMGenValid(ui32Gen));
|
||
|
ASSERT((ui32Group == PWM_FAULT_GROUP_0) ||
|
||
|
(ui32Group == PWM_FAULT_GROUP_1));
|
||
|
|
||
|
//
|
||
|
// Return the current fault triggers.
|
||
|
//
|
||
|
if (ui32Group == PWM_FAULT_GROUP_0)
|
||
|
{
|
||
|
return (HWREG(PWM_GEN_BADDR(ui32Base, ui32Gen) + PWM_O_X_FLTSRC0));
|
||
|
}
|
||
|
else
|
||
|
{
|
||
|
return (HWREG(PWM_GEN_BADDR(ui32Base, ui32Gen) + PWM_O_X_FLTSRC1));
|
||
|
}
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Returns the current state of the fault triggers for a given PWM generator.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32Gen is the PWM generator for which fault trigger states are
|
||
|
//! being queried. This parameter must be one of \b PWM_GEN_0, \b PWM_GEN_1,
|
||
|
//! \b PWM_GEN_2, or \b PWM_GEN_3.
|
||
|
//! \param ui32Group indicates the subset of faults that are being queried.
|
||
|
//! This parameter must be \b PWM_FAULT_GROUP_0 or \b PWM_FAULT_GROUP_1.
|
||
|
//!
|
||
|
//! This function allows an application to query the current state of each of
|
||
|
//! the fault trigger inputs to a given PWM generator. The current state of
|
||
|
//! each fault trigger input is returned unless PWMGenConfigure() has
|
||
|
//! previously been called with flag \b PWM_GEN_MODE_FAULT_LATCHED in the
|
||
|
//! \e ui32Config parameter, in which case the returned status is the latched
|
||
|
//! fault trigger status.
|
||
|
//!
|
||
|
//! If latched faults are configured, the application must call
|
||
|
//! PWMGenFaultClear() to clear each trigger.
|
||
|
//!
|
||
|
//! \return Returns the current state of the fault triggers for the given PWM
|
||
|
//! generator. A set bit indicates that the associated trigger is active.
|
||
|
//! For \b PWM_FAULT_GROUP_0, the returned value is a logical OR of
|
||
|
//! \b PWM_FAULT_FAULT0, \b PWM_FAULT_FAULT1, \b PWM_FAULT_FAULT2, or
|
||
|
//! \b PWM_FAULT_FAULT3. For \b PWM_FAULT_GROUP_1, the return value is the
|
||
|
//! logical OR of \b PWM_FAULT_DCMP0, \b PWM_FAULT_DCMP1,
|
||
|
//! \b PWM_FAULT_DCMP2, \b PWM_FAULT_DCMP3, \b PWM_FAULT_DCMP4,
|
||
|
//! \b PWM_FAULT_DCMP5, \b PWM_FAULT_DCMP6, or \b PWM_FAULT_DCMP7.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
uint32_t
|
||
|
PWMGenFaultStatus(uint32_t ui32Base, uint32_t ui32Gen,
|
||
|
uint32_t ui32Group)
|
||
|
{
|
||
|
//
|
||
|
// Check for valid parameters.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT(_PWMGenValid(ui32Gen));
|
||
|
ASSERT((ui32Group == PWM_FAULT_GROUP_0) ||
|
||
|
(ui32Group == PWM_FAULT_GROUP_1));
|
||
|
|
||
|
//
|
||
|
// Return the current fault status.
|
||
|
//
|
||
|
if (ui32Group == PWM_FAULT_GROUP_0)
|
||
|
{
|
||
|
return (HWREG(PWM_GEN_EXT_BADDR(ui32Base, ui32Gen) + PWM_O_X_FLTSTAT0));
|
||
|
}
|
||
|
else
|
||
|
{
|
||
|
return (HWREG(PWM_GEN_EXT_BADDR(ui32Base, ui32Gen) + PWM_O_X_FLTSTAT1));
|
||
|
}
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Clears one or more latched fault triggers for a given PWM generator.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32Gen is the PWM generator for which fault trigger states are
|
||
|
//! being queried. This parameter must be one of \b PWM_GEN_0, \b PWM_GEN_1,
|
||
|
//! \b PWM_GEN_2, or \b PWM_GEN_3.
|
||
|
//! \param ui32Group indicates the subset of faults that are being queried.
|
||
|
//! This parameter must be \b PWM_FAULT_GROUP_0 or \b PWM_FAULT_GROUP_1.
|
||
|
//! \param ui32FaultTriggers is the set of fault triggers which are to be
|
||
|
//! cleared.
|
||
|
//!
|
||
|
//! This function allows an application to clear the fault triggers for a
|
||
|
//! given PWM generator. This function is only required if PWMGenConfigure()
|
||
|
//! has previously been called with flag \b PWM_GEN_MODE_FAULT_LATCHED in
|
||
|
//! parameter \e ui32Config.
|
||
|
//!
|
||
|
//! \return None.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
void
|
||
|
PWMGenFaultClear(uint32_t ui32Base, uint32_t ui32Gen,
|
||
|
uint32_t ui32Group, uint32_t ui32FaultTriggers)
|
||
|
{
|
||
|
//
|
||
|
// Check for valid parameters.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT(_PWMGenValid(ui32Gen));
|
||
|
ASSERT((ui32Group == PWM_FAULT_GROUP_0) ||
|
||
|
(ui32Group == PWM_FAULT_GROUP_1));
|
||
|
ASSERT((ui32Group == PWM_FAULT_GROUP_0) &&
|
||
|
((ui32FaultTriggers & ~(PWM_FAULT_FAULT0 | PWM_FAULT_FAULT1 |
|
||
|
PWM_FAULT_FAULT2 | PWM_FAULT_FAULT3)) ==
|
||
|
0));
|
||
|
ASSERT((ui32Group == PWM_FAULT_GROUP_1) &&
|
||
|
((ui32FaultTriggers & ~(PWM_FAULT_DCMP0 | PWM_FAULT_DCMP1 |
|
||
|
PWM_FAULT_DCMP2 | PWM_FAULT_DCMP3 |
|
||
|
PWM_FAULT_DCMP4 | PWM_FAULT_DCMP5 |
|
||
|
PWM_FAULT_DCMP6 | PWM_FAULT_DCMP7)) == 0));
|
||
|
|
||
|
//
|
||
|
// Clear the given faults.
|
||
|
//
|
||
|
if (ui32Group == PWM_FAULT_GROUP_0)
|
||
|
{
|
||
|
HWREG(PWM_GEN_EXT_BADDR(ui32Base, ui32Gen) + PWM_O_X_FLTSTAT0) =
|
||
|
ui32FaultTriggers;
|
||
|
}
|
||
|
else
|
||
|
{
|
||
|
HWREG(PWM_GEN_EXT_BADDR(ui32Base, ui32Gen) + PWM_O_X_FLTSTAT1) =
|
||
|
ui32FaultTriggers;
|
||
|
}
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
///
|
||
|
//! Sets the PWM clock configuration.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32Config is the configuration for the PWM clock; it must be one of
|
||
|
//! \b PWM_SYSCLK_DIV_1, \b PWM_SYSCLK_DIV_2, \b PWM_SYSCLK_DIV_4,
|
||
|
//! \b PWM_SYSCLK_DIV_8, \b PWM_SYSCLK_DIV_16, \b PWM_SYSCLK_DIV_32, or
|
||
|
//! \b PWM_SYSCLK_DIV_64.
|
||
|
//!
|
||
|
//! This function sets the PWM clock divider as the PWM clock source. It also
|
||
|
//! configures the clock frequency to the PWM module as a division of the
|
||
|
//! system clock. This clock is used by the PWM module to generate PWM
|
||
|
//! signals; its rate forms the basis for all PWM signals.
|
||
|
//!
|
||
|
//! \note The clocking of the PWM is dependent upon the system clock rate as
|
||
|
//! configured by SysCtlClockFreqSet().
|
||
|
//!
|
||
|
//! \return None.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
void
|
||
|
PWMClockSet(uint32_t ui32Base, uint32_t ui32Config)
|
||
|
{
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT((ui32Config == PWM_SYSCLK_DIV_2) ||
|
||
|
(ui32Config == PWM_SYSCLK_DIV_4) ||
|
||
|
(ui32Config == PWM_SYSCLK_DIV_8) ||
|
||
|
(ui32Config == PWM_SYSCLK_DIV_16) ||
|
||
|
(ui32Config == PWM_SYSCLK_DIV_32) ||
|
||
|
(ui32Config == PWM_SYSCLK_DIV_64));
|
||
|
|
||
|
//
|
||
|
// Set the PWM clock configuration into the PWM clock configuration
|
||
|
// register.
|
||
|
//
|
||
|
HWREG(ui32Base + PWM_O_CC) = ((HWREG(ui32Base + PWM_O_CC) &
|
||
|
~(PWM_CC_USEPWM | PWM_CC_PWMDIV_M)) |
|
||
|
ui32Config);
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Gets the current PWM clock configuration.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//!
|
||
|
//! This function returns the current PWM clock configuration.
|
||
|
//!
|
||
|
//! \return Returns the current PWM clock configuration; is one of
|
||
|
//! \b PWM_SYSCLK_DIV_1, \b PWM_SYSCLK_DIV_2, \b PWM_SYSCLK_DIV_4,
|
||
|
//! \b PWM_SYSCLK_DIV_8, \b PWM_SYSCLK_DIV_16, \b PWM_SYSCLK_DIV_32,
|
||
|
//! or \b PWM_SYSCLK_DIV_64.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
uint32_t
|
||
|
PWMClockGet(uint32_t ui32Base)
|
||
|
{
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
|
||
|
//
|
||
|
// Return the current PWM clock configuration. Make sure that
|
||
|
// PWM_SYSCLK_DIV_1 is returned in all cases where the divider is disabled.
|
||
|
//
|
||
|
if (!(HWREG(ui32Base + PWM_O_CC) & PWM_CC_USEPWM))
|
||
|
{
|
||
|
//
|
||
|
// The divider is not active so reflect this in the value we return.
|
||
|
//
|
||
|
return (PWM_SYSCLK_DIV_1);
|
||
|
}
|
||
|
else
|
||
|
{
|
||
|
//
|
||
|
// The divider is active so directly return the masked register value.
|
||
|
//
|
||
|
return (HWREG(ui32Base + PWM_O_CC) & (PWM_CC_USEPWM | PWM_CC_PWMDIV_M));
|
||
|
}
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
//! Sets the update mode or synchronization mode to the PWM outputs.
|
||
|
//!
|
||
|
//! \param ui32Base is the base address of the PWM module.
|
||
|
//! \param ui32PWMOutBits are the PWM outputs to be modified. This parameter
|
||
|
//! must be the logical OR of any of \b PWM_OUT_0_BIT, \b PWM_OUT_1_BIT,
|
||
|
//! \b PWM_OUT_2_BIT, \b PWM_OUT_3_BIT, \b PWM_OUT_4_BIT, \b PWM_OUT_5_BIT,
|
||
|
//! \b PWM_OUT_6_BIT, or \b PWM_OUT_7_BIT.
|
||
|
//! \param ui32Mode specifies the enable update mode to use when enabling or
|
||
|
//! disabling PWM outputs.
|
||
|
//!
|
||
|
//! This function sets one of three possible update modes to enable or disable
|
||
|
//! the requested PWM outputs. The \e ui32Mode parameter controls when changes
|
||
|
//! made via calls to PWMOutputState() take effect. Possible values are:
|
||
|
//!
|
||
|
//! - \b PWM_OUTPUT_MODE_NO_SYNC, which enables/disables changes to take effect
|
||
|
//! immediately.
|
||
|
//! - \b PWM_OUTPUT_MODE_SYNC_LOCAL, which causes changes to take effect when
|
||
|
//! the local PWM generator's count next reaches 0.
|
||
|
//! - \b PWM_OUTPUT_MODE_SYNC_GLOBAL, which causes changes to take effect when
|
||
|
//! the local PWM generator's count next reaches 0 following a call to
|
||
|
//! PWMSyncUpdate() which specifies the same generator in its \e ui32GenBits
|
||
|
//! parameter.
|
||
|
//!
|
||
|
//! \return None.
|
||
|
//
|
||
|
//*****************************************************************************
|
||
|
void
|
||
|
PWMOutputUpdateMode(uint32_t ui32Base, uint32_t ui32PWMOutBits,
|
||
|
uint32_t ui32Mode)
|
||
|
{
|
||
|
uint_fast8_t ui8Index;
|
||
|
uint32_t ui32PWMOutputMask;
|
||
|
uint32_t ui32UpdateValueMask;
|
||
|
uint32_t ui32UpdateValue;
|
||
|
uint32_t ui32Temp;
|
||
|
|
||
|
//
|
||
|
// Check the arguments.
|
||
|
//
|
||
|
ASSERT(ui32Base == PWM0_BASE);
|
||
|
ASSERT(!(ui32PWMOutBits & ~(PWM_OUT_0_BIT | PWM_OUT_1_BIT | PWM_OUT_2_BIT |
|
||
|
PWM_OUT_3_BIT | PWM_OUT_4_BIT | PWM_OUT_5_BIT |
|
||
|
PWM_OUT_6_BIT | PWM_OUT_7_BIT)));
|
||
|
ASSERT((ui32Mode == PWM_OUTPUT_MODE_NO_SYNC) ||
|
||
|
(ui32Mode == PWM_OUTPUT_MODE_SYNC_LOCAL) ||
|
||
|
(ui32Mode == PWM_OUTPUT_MODE_SYNC_GLOBAL));
|
||
|
|
||
|
//
|
||
|
// Initialize the local variables
|
||
|
//
|
||
|
ui8Index = 0;
|
||
|
ui32PWMOutputMask = 1;
|
||
|
ui32UpdateValue = 0;
|
||
|
ui32UpdateValueMask = 0;
|
||
|
|
||
|
//
|
||
|
// Loop to find out which PWM outputs are to be modified.
|
||
|
//
|
||
|
while (ui8Index < 8)
|
||
|
{
|
||
|
//
|
||
|
// Check if this PWM output is to be modified.
|
||
|
//
|
||
|
if (ui32PWMOutputMask & ui32PWMOutBits)
|
||
|
{
|
||
|
//
|
||
|
// Set the update mode value for the requested PWM output by
|
||
|
// writing to the appropriate field.
|
||
|
//
|
||
|
ui32UpdateValue |= ui32Mode << (ui8Index * 2);
|
||
|
|
||
|
//
|
||
|
// Compute the mask for the bits to be updated.
|
||
|
//
|
||
|
ui32UpdateValueMask |= 3 << (ui8Index * 2);
|
||
|
}
|
||
|
|
||
|
//
|
||
|
// Update the PWM output to be checked and the index.
|
||
|
//
|
||
|
ui32PWMOutputMask = ui32PWMOutputMask << 1;
|
||
|
ui8Index++;
|
||
|
}
|
||
|
|
||
|
//
|
||
|
// Read the Enable Update register and mask the bits that are to be
|
||
|
// updated.
|
||
|
//
|
||
|
ui32Temp = ~ui32UpdateValueMask & HWREG(ui32Base + PWM_O_ENUPD);
|
||
|
|
||
|
//
|
||
|
// Write the updated values to Enable Update register.
|
||
|
//
|
||
|
HWREG(ui32Base + PWM_O_ENUPD) = ui32Temp | ui32UpdateValue;
|
||
|
}
|
||
|
|
||
|
//*****************************************************************************
|
||
|
//
|
||
|
// Close the Doxygen group.
|
||
|
//! @}
|
||
|
//
|
||
|
//*****************************************************************************
|