rt-thread-official/components/net/freemodbus/modbus/include/mb_m.h

403 lines
18 KiB
C
Raw Normal View History

/*
* FreeModbus Libary: A portable Modbus implementation for Modbus ASCII/RTU.
* Copyright (C) 2013 Armink <armink.ztl@gmail.com>
* All rights reserved.
*
* Redistribution and use in source and binary forms, with or without
* modification, are permitted provided that the following conditions
* are met:
* 1. Redistributions of source code must retain the above copyright
* notice, this list of conditions and the following disclaimer.
* 2. Redistributions in binary form must reproduce the above copyright
* notice, this list of conditions and the following disclaimer in the
* documentation and/or other materials provided with the distribution.
* 3. The name of the author may not be used to endorse or promote products
* derived from this software without specific prior written permission.
*
* THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS'' AND ANY EXPRESS OR
* IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
* OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.
* IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT,
* INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
* NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
* DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
* THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
* (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF
* THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
*
* File: $Id: mb_m.h,v 1.60 2013/09/03 10:20:05 Armink Add Master Functions $
*/
#ifndef _MB_M_H
#define _MB_M_H
#ifdef __cplusplus
PR_BEGIN_EXTERN_C
#endif
/*! \defgroup modbus Modbus
* \code #include "mb_m.h" \endcode
*
* This module defines the interface for the application. It contains
* the basic functions and types required to use the Modbus Master protocol stack.
* A typical application will want to call eMBMasterInit() first. If the device
* is ready to answer network requests it must then call eMBEnable() to activate
* the protocol stack. In the main loop the function eMBMasterPoll() must be called
* periodically. The time interval between pooling depends on the configured
* Modbus timeout. If an RTOS is available a separate task should be created
* and the task should always call the function eMBMasterPoll().
*
* \code
* // Initialize protocol stack in RTU mode for a Master
* eMBMasterInit( MB_RTU, 38400, MB_PAR_EVEN );
* // Enable the Modbus Protocol Stack.
* eMBMasterEnable( );
* for( ;; )
* {
* // Call the main polling loop of the Modbus Master protocol stack.
* eMBMasterPoll( );
* ...
* }
* \endcode
*/
/* ----------------------- Defines ------------------------------------------*/
/*! \ingroup modbus
* \brief Use the default Modbus Master TCP port (502)
*/
#define MB_MASTER_TCP_PORT_USE_DEFAULT 0
/* ----------------------- Type definitions ---------------------------------*/
/*! \ingroup modbus
* \brief Errorcodes used by all function in the Master request.
*/
typedef enum
{
MB_MRE_NO_ERR, /*!< no error. */
MB_MRE_NO_REG, /*!< illegal register address. */
MB_MRE_ILL_ARG, /*!< illegal argument. */
MB_MRE_REV_DATA, /*!< receive data error. */
MB_MRE_TIMEDOUT, /*!< timeout error occurred. */
MB_MRE_MASTER_BUSY, /*!< master is busy now. */
MB_MRE_EXE_FUN /*!< execute function error. */
} eMBMasterReqErrCode;
/*! \ingroup modbus
* \brief TimerMode is Master 3 kind of Timer modes.
*/
typedef enum
{
MB_TMODE_T35, /*!< Master receive frame T3.5 timeout. */
MB_TMODE_RESPOND_TIMEOUT, /*!< Master wait respond for slave. */
MB_TMODE_CONVERT_DELAY /*!< Master sent broadcast ,then delay sometime.*/
}eMBMasterTimerMode;
/* ----------------------- Function prototypes ------------------------------*/
/*! \ingroup modbus
* \brief Initialize the Modbus Master protocol stack.
*
* This functions initializes the ASCII or RTU module and calls the
* init functions of the porting layer to prepare the hardware. Please
* note that the receiver is still disabled and no Modbus frames are
* processed until eMBMasterEnable( ) has been called.
*
* \param eMode If ASCII or RTU mode should be used.
* \param ucPort The port to use. E.g. 1 for COM1 on windows. This value
* is platform dependent and some ports simply choose to ignore it.
* \param ulBaudRate The baudrate. E.g. 19200. Supported baudrates depend
* on the porting layer.
* \param eParity Parity used for serial transmission.
*
* \return If no error occurs the function returns eMBErrorCode::MB_ENOERR.
* The protocol is then in the disabled state and ready for activation
* by calling eMBMasterEnable( ). Otherwise one of the following error codes
* is returned:
* - eMBErrorCode::MB_EPORTERR IF the porting layer returned an error.
*/
eMBErrorCode eMBMasterInit( eMBMode eMode, UCHAR ucPort,
ULONG ulBaudRate, eMBParity eParity );
/*! \ingroup modbus
* \brief Initialize the Modbus Master protocol stack for Modbus TCP.
*
* This function initializes the Modbus TCP Module. Please note that
* frame processing is still disabled until eMBEnable( ) is called.
*
* \param usTCPPort The TCP port to listen on.
* \return If the protocol stack has been initialized correctly the function
* returns eMBErrorCode::MB_ENOERR. Otherwise one of the following error
* codes is returned:
* - eMBErrorCode::MB_EINVAL If the slave address was not valid. Valid
* slave addresses are in the range 1 - 247.
* - eMBErrorCode::MB_EPORTERR IF the porting layer returned an error.
*/
eMBErrorCode eMBMasterTCPInit( USHORT usTCPPort );
/*! \ingroup modbus
* \brief Release resources used by the protocol stack.
*
* This function disables the Modbus Master protocol stack and release all
* hardware resources. It must only be called when the protocol stack
* is disabled.
*
* \note Note all ports implement this function. A port which wants to
* get an callback must define the macro MB_PORT_HAS_CLOSE to 1.
*
* \return If the resources where released it return eMBErrorCode::MB_ENOERR.
* If the protocol stack is not in the disabled state it returns
* eMBErrorCode::MB_EILLSTATE.
*/
eMBErrorCode eMBMasterClose( void );
/*! \ingroup modbus
* \brief Enable the Modbus Master protocol stack.
*
* This function enables processing of Modbus Master frames. Enabling the protocol
* stack is only possible if it is in the disabled state.
*
* \return If the protocol stack is now in the state enabled it returns
* eMBErrorCode::MB_ENOERR. If it was not in the disabled state it
* return eMBErrorCode::MB_EILLSTATE.
*/
eMBErrorCode eMBMasterEnable( void );
/*! \ingroup modbus
* \brief Disable the Modbus Master protocol stack.
*
* This function disables processing of Modbus frames.
*
* \return If the protocol stack has been disabled it returns
* eMBErrorCode::MB_ENOERR. If it was not in the enabled state it returns
* eMBErrorCode::MB_EILLSTATE.
*/
eMBErrorCode eMBMasterDisable( void );
/*! \ingroup modbus
* \brief The main pooling loop of the Modbus Master protocol stack.
*
* This function must be called periodically. The timer interval required
* is given by the application dependent Modbus slave timeout. Internally the
* function calls xMBMasterPortEventGet() and waits for an event from the receiver or
* transmitter state machines.
*
* \return If the protocol stack is not in the enabled state the function
* returns eMBErrorCode::MB_EILLSTATE. Otherwise it returns
* eMBErrorCode::MB_ENOERR.
*/
eMBErrorCode eMBMasterPoll( void );
/*! \ingroup modbus
* \brief Registers a callback handler for a given function code.
*
* This function registers a new callback handler for a given function code.
* The callback handler supplied is responsible for interpreting the Modbus PDU and
* the creation of an appropriate response. In case of an error it should return
* one of the possible Modbus exceptions which results in a Modbus exception frame
* sent by the protocol stack.
*
* \param ucFunctionCode The Modbus function code for which this handler should
* be registers. Valid function codes are in the range 1 to 127.
* \param pxHandler The function handler which should be called in case
* such a frame is received. If \c NULL a previously registered function handler
* for this function code is removed.
*
* \return eMBErrorCode::MB_ENOERR if the handler has been installed. If no
* more resources are available it returns eMBErrorCode::MB_ENORES. In this
* case the values in mbconfig.h should be adjusted. If the argument was not
* valid it returns eMBErrorCode::MB_EINVAL.
*/
eMBErrorCode eMBMasterRegisterCB( UCHAR ucFunctionCode,
pxMBFunctionHandler pxHandler );
/* ----------------------- Callback -----------------------------------------*/
/*! \defgroup modbus_master registers Modbus Registers
* \code #include "mb_m.h" \endcode
* The protocol stack does not internally allocate any memory for the
* registers. This makes the protocol stack very small and also usable on
* low end targets. In addition the values don't have to be in the memory
* and could for example be stored in a flash.<br>
* Whenever the protocol stack requires a value it calls one of the callback
* function with the register address and the number of registers to read
* as an argument. The application should then read the actual register values
* (for example the ADC voltage) and should store the result in the supplied
* buffer.<br>
* If the protocol stack wants to update a register value because a write
* register function was received a buffer with the new register values is
* passed to the callback function. The function should then use these values
* to update the application register values.
*/
/*! \ingroup modbus_registers
* \brief Callback function used if the value of a <em>Input Register</em>
* is required by the protocol stack. The starting register address is given
* by \c usAddress and the last register is given by <tt>usAddress +
* usNRegs - 1</tt>.
*
* \param pucRegBuffer A buffer where the callback function should write
* the current value of the modbus registers to.
* \param usAddress The starting address of the register. Input registers
* are in the range 1 - 65535.
* \param usNRegs Number of registers the callback function must supply.
*
* \return The function must return one of the following error codes:
* - eMBErrorCode::MB_ENOERR If no error occurred. In this case a normal
* Modbus response is sent.
* - eMBErrorCode::MB_ENOREG If the application does not map an coils
* within the requested address range. In this case a
* <b>ILLEGAL DATA ADDRESS</b> is sent as a response.
*/
eMBErrorCode eMBMasterRegInputCB( UCHAR * pucRegBuffer, USHORT usAddress,
USHORT usNRegs );
/*! \ingroup modbus_registers
* \brief Callback function used if a <em>Holding Register</em> value is
* read or written by the protocol stack. The starting register address
* is given by \c usAddress and the last register is given by
* <tt>usAddress + usNRegs - 1</tt>.
*
* \param pucRegBuffer If the application registers values should be updated the
* buffer points to the new registers values. If the protocol stack needs
* to now the current values the callback function should write them into
* this buffer.
* \param usAddress The starting address of the register.
* \param usNRegs Number of registers to read or write.
* \param eMode If eMBRegisterMode::MB_REG_WRITE the application register
* values should be updated from the values in the buffer. For example
* this would be the case when the Modbus master has issued an
* <b>WRITE SINGLE REGISTER</b> command.
* If the value eMBRegisterMode::MB_REG_READ the application should copy
* the current values into the buffer \c pucRegBuffer.
*
* \return The function must return one of the following error codes:
* - eMBErrorCode::MB_ENOERR If no error occurred. In this case a normal
* Modbus response is sent.
* - eMBErrorCode::MB_ENOREG If the application does not map an coils
* within the requested address range. In this case a
* <b>ILLEGAL DATA ADDRESS</b> is sent as a response.
*/
eMBErrorCode eMBMasterRegHoldingCB( UCHAR * pucRegBuffer, USHORT usAddress,
USHORT usNRegs, eMBRegisterMode eMode );
/*! \ingroup modbus_registers
* \brief Callback function used if a <em>Coil Register</em> value is
* read or written by the protocol stack. If you are going to use
* this function you might use the functions xMBUtilSetBits( ) and
* xMBUtilGetBits( ) for working with bitfields.
*
* \param pucRegBuffer The bits are packed in bytes where the first coil
* starting at address \c usAddress is stored in the LSB of the
* first byte in the buffer <code>pucRegBuffer</code>.
* If the buffer should be written by the callback function unused
* coil values (I.e. if not a multiple of eight coils is used) should be set
* to zero.
* \param usAddress The first coil number.
* \param usNCoils Number of coil values requested.
* \param eMode If eMBRegisterMode::MB_REG_WRITE the application values should
* be updated from the values supplied in the buffer \c pucRegBuffer.
* If eMBRegisterMode::MB_REG_READ the application should store the current
* values in the buffer \c pucRegBuffer.
*
* \return The function must return one of the following error codes:
* - eMBErrorCode::MB_ENOERR If no error occurred. In this case a normal
* Modbus response is sent.
* - eMBErrorCode::MB_ENOREG If the application does not map an coils
* within the requested address range. In this case a
* <b>ILLEGAL DATA ADDRESS</b> is sent as a response.
*/
eMBErrorCode eMBMasterRegCoilsCB( UCHAR * pucRegBuffer, USHORT usAddress,
USHORT usNCoils, eMBRegisterMode eMode );
/*! \ingroup modbus_registers
* \brief Callback function used if a <em>Input Discrete Register</em> value is
* read by the protocol stack.
*
* If you are going to use his function you might use the functions
* xMBUtilSetBits( ) and xMBUtilGetBits( ) for working with bitfields.
*
* \param pucRegBuffer The buffer should be updated with the current
* coil values. The first discrete input starting at \c usAddress must be
* stored at the LSB of the first byte in the buffer. If the requested number
* is not a multiple of eight the remaining bits should be set to zero.
* \param usAddress The starting address of the first discrete input.
* \param usNDiscrete Number of discrete input values.
* \return The function must return one of the following error codes:
* - eMBErrorCode::MB_ENOERR If no error occurred. In this case a normal
* Modbus response is sent.
* - eMBErrorCode::MB_ENOREG If the application does not map an coils
* within the requested address range. In this case a
* <b>ILLEGAL DATA ADDRESS</b> is sent as a response.
*/
eMBErrorCode eMBMasterRegDiscreteCB( UCHAR * pucRegBuffer, USHORT usAddress,
USHORT usNDiscrete );
/*! \ingroup modbus
*\brief These Modbus functions are called for user when Modbus run in Master Mode.
*/
eMBMasterReqErrCode
eMBMasterReqReadInputRegister( UCHAR ucSndAddr, USHORT usRegAddr, USHORT usNRegs, LONG lTimeOut );
eMBMasterReqErrCode
eMBMasterReqWriteHoldingRegister( UCHAR ucSndAddr, USHORT usRegAddr, USHORT usRegData, LONG lTimeOut );
eMBMasterReqErrCode
eMBMasterReqWriteMultipleHoldingRegister( UCHAR ucSndAddr, USHORT usRegAddr,
USHORT usNRegs, USHORT * pusDataBuffer, LONG lTimeOut );
eMBMasterReqErrCode
eMBMasterReqReadHoldingRegister( UCHAR ucSndAddr, USHORT usRegAddr, USHORT usNRegs, LONG lTimeOut );
eMBMasterReqErrCode
eMBMasterReqReadWriteMultipleHoldingRegister( UCHAR ucSndAddr,
USHORT usReadRegAddr, USHORT usNReadRegs, USHORT * pusDataBuffer,
USHORT usWriteRegAddr, USHORT usNWriteRegs, LONG lTimeOut );
eMBMasterReqErrCode
eMBMasterReqReadCoils( UCHAR ucSndAddr, USHORT usCoilAddr, USHORT usNCoils, LONG lTimeOut );
eMBMasterReqErrCode
eMBMasterReqWriteCoil( UCHAR ucSndAddr, USHORT usCoilAddr, USHORT usCoilData, LONG lTimeOut );
eMBMasterReqErrCode
eMBMasterReqWriteMultipleCoils( UCHAR ucSndAddr,
USHORT usCoilAddr, USHORT usNCoils, UCHAR * pucDataBuffer, LONG lTimeOut );
eMBMasterReqErrCode
eMBMasterReqReadDiscreteInputs( UCHAR ucSndAddr, USHORT usDiscreteAddr, USHORT usNDiscreteIn, LONG lTimeOut );
eMBException
eMBMasterFuncReportSlaveID( UCHAR * pucFrame, USHORT * usLen );
eMBException
eMBMasterFuncReadInputRegister( UCHAR * pucFrame, USHORT * usLen );
eMBException
eMBMasterFuncReadHoldingRegister( UCHAR * pucFrame, USHORT * usLen );
eMBException
eMBMasterFuncWriteHoldingRegister( UCHAR * pucFrame, USHORT * usLen );
eMBException
eMBMasterFuncWriteMultipleHoldingRegister( UCHAR * pucFrame, USHORT * usLen );
eMBException
eMBMasterFuncReadCoils( UCHAR * pucFrame, USHORT * usLen );
eMBException
eMBMasterFuncWriteCoil( UCHAR * pucFrame, USHORT * usLen );
eMBException
eMBMasterFuncWriteMultipleCoils( UCHAR * pucFrame, USHORT * usLen );
eMBException
eMBMasterFuncReadDiscreteInputs( UCHAR * pucFrame, USHORT * usLen );
eMBException
eMBMasterFuncReadWriteMultipleHoldingRegister( UCHAR * pucFrame, USHORT * usLen );
/*<2A><> \ingroup modbus
*\brief These functions are interface for Modbus Master
*/
void vMBMasterGetPDUSndBuf( UCHAR ** pucFrame );
UCHAR ucMBMasterGetDestAddress( void );
void vMBMasterSetDestAddress( UCHAR Address );
BOOL xMBMasterGetCBRunInMasterMode( void );
void vMBMasterSetCBRunInMasterMode( BOOL IsMasterMode );
USHORT usMBMasterGetPDUSndLength( void );
void vMBMasterSetPDUSndLength( USHORT SendPDULength );
void vMBMasterSetCurTimerMode( eMBMasterTimerMode eMBTimerMode );
BOOL xMBMasterRequestIsBroadcast( void );
eMBMasterErrorEventType eMBMasterGetErrorType( void );
void vMBMasterSetErrorType( eMBMasterErrorEventType errorType );
eMBMasterReqErrCode eMBMasterWaitRequestFinish( void );
/* ----------------------- Callback -----------------------------------------*/
#ifdef __cplusplus
PR_END_EXTERN_C
#endif
#endif