Previously, the number of command line args was not checked for
cygwin process. Due to this, segmentation fault was caused if too
many command line args are specified.
https://cygwin.com/pipermail/cygwin/2023-August/254333.html
Since char *argv[argc + 1] is placed on the stack in dll_crt0_1(),
STATUS_STACK_OVERFLOW occurs if the stack does not have enough
space.
With this patch, char *argv[] is placed in heap instead of stack
and ARG_MAX is increased from 32000 to 2097152 which is default
value of Linux. The argument length is also compared with ARG_MAX
and spawnve() returns E2BIG if it is too long.
Reported-by: Ed Morton
Reviewed-by: Corinna Vinschen <corinna@vinschen.de>
Signed-off-by: Takashi Yano <takashi.yano@nifty.ne.jp>
After the commit fbfea31dd9, switch_to_nat_pipe is not cleared
properly when non-cygwin app is terminated in the case where the
pseudo console is disabled. This is because get_winpid_to_hand_over()
sometimes returns PID of cygwin process even though it should return
only PID of non-cygwin process. This patch fixes the issue by adding
a new argument which requests only PID of non-cygwin process to
get_console_process_id().
Fixes: fbfea31dd9 ("Cygwin: pty: Avoid cutting the branch the pty master is sitting on.")
Signed-off-by: Takashi Yano <takashi.yano@nifty.ne.jp>